background image

NEVER LEAVE HEATER UNATTENDED WHILE BURNING 

OR WHILE CONNECTED TO A POWER SOURCE

© 2017, Pinnacle Climate Technologies, Inc. 

Kerosene Forced Air Heater User’s Manual 

Fueling The Heater:
Kerosene (K-1)

For optimal performance of this heater, it is strongly 

suggested that K-1 kerosene be used. K-1 kerosene 

has been refined to virtually eliminate contaminants, 

such as sulfur, which can cause a rotten egg odor during 

the operation of the heater. Using diesel fuel can cause 

excess soot production. Do not use Bio-Diesel as this 

fuel will damage your heater’s seals and filter.

 - CSA certified for use with K-1 kerosene,  

no. 1 & no. 2 diesel, JP8/Jet A Fuel,  

no. 1 and no. 2 fuel oil.

DO NOT use any fuel that is not approved above.
 - NEVER use fuel such as, benzene, alcohol, white glass, 

camp stove fuel, paint thinners, or other oil compounds in 

this heater. THESE ARE VOLATILE FUELS THAT CAN 

CAUSE A FIRE OR EXPLOSION.

- NEVER store kerosene in the living space. Kerosene should 

be stored in a well ventilated area outside the living area.

 - NEVER store kerosene in direct sunlight or near a source 

of heat.

 - NEVER use kerosene that has been stored from one season to 

the next. Kerosene deteriorates over time. OLD KEROSENE 

WILL NOT BURN PROPERLY IN THIS HEATER. 

NOTE: Kerosene should only be stored in a blue 

container that is clearly marked “Kerosene.” Never store 

kerosene in a red container. Red is associated with 

gasoline.

Ventilation:
 - Risk of indoor air pollution and Carbon Monoxide 

Poisoning. Use heater only in well ventilated areas.

 - Refer to Safety Information on page 1 for information 

about Carbon Monoxide Poisoning.

 - ALWAYS

 provide a fresh air opening in the heated space 

of at least three square feet (2,800 sq. cm) for each 

100,00 Btu / Hr. of heater output. Provide a larger opening 

if more heaters are being used. 

Minimum Ventilation Opening Needed

45-KFA

75T-KFA

135T-KFA

1.4 ft.²

2.3 ft.²

4.1 ft.²

1250 cm²

2090 cm²

3760 cm²

Minimum Ventilation Opening Needed

175T-KFA

190T-KFA

215T-KFA

5.3 ft.²

5.7 ft.²

6.5 ft.²

3760 cm²

5290 cm²

5990 cm²

Operation

NEVER FILL 

THE FUEL TANK 

INDOORS. 

ALWAYS FILL THE TANK OUTDOORS. 

BE SURE THAT THE HEATER IS ON 

LEVEL GROUND WHEN FUELING, AND 

NEVER OVERFILL THE TANK.

CAUTION

NEVER REFUEL 

THIS HEATER 

WHILE IT IS HOT 

OR OPERATING. FIRE OR EXPLOSION 

COULD RESULT.

 

CARBON MONOXIDE POISONING MAY LEAD 

TO DEATH!

5

DANGER

DO NOT USE 

GASOLINE OR 

CRANKCASE 

DRAININGS.

 

WARNING

DANGER

Summary of Contents for Remington REM-135T-KFA-O

Page 1: ...to Ventilation on Page 5 FACTORY ID 001 Safety Information FIRE BURN INHALATION AND EXPLOSION HAZARD Keep combustibles such as building materials paper or cardboard a safe distance away from the heate...

Page 2: ...use for temporary heating of buildings under construction alteration or repair Direct fired means that all of the combustion products of the heater enter the heated space This appliance is rated at 98...

Page 3: ...ls away from this heater Minimum Clearance From Combustibles 45 190T KFA 215T KFA Top 4 ft 4 ft Sides 4 ft 4 ft Front 8 ft 10 ft ALWAYS locate heater on a stable and level surface If your heater is eq...

Page 4: ...Manual 3 Wiring Diagrams 45 KFA 75T 215T KFA Assembly Instructions What s In The Box Models 45 KFA 75T KFA Remove the heater and all packaging materials from the shipping carton Note Save the box and...

Page 5: ...lace heater on wheel support and line up holes on the fuel tank lip 5 Attach front handle with 2 long screws 50 mm and 2 nuts through the second hole from the front on both sides of the tank lip and w...

Page 6: ...R use kerosene that has been stored from one season to the next Kerosene deteriorates over time OLD KEROSENE WILL NOT BURN PROPERLY IN THIS HEATER NOTE Kerosene should only be stored in a blue contain...

Page 7: ...temperature display will indicate the following When the temperature is less than 0 F the display says LO When the temperature is more that 99 F the display says HI Between 0 F and 99 F the display s...

Page 8: ...starting the heater FUEL FILTER The fuel filter should be cleaned at least twice per heating season Clean the filter by rinsing it in clean K 1 Kerosene Contaminated fuel could make cleaning the fuel...

Page 9: ...ESSURE While heater is operating turn adjusting screw clockwise to increase counter clockwise to decrease pressure Correct pump pressure is as follows Model Number Pump Pressure 45 KFA 3 0 PSI 75T KFA...

Page 10: ...proper spacing with rotor 1 Fill tank with fresh kerosene 2 Adjust pump pressure 3 Clean replace spark plug 4 Clean replace fuel filter 5 Clean replace nozzle 6 Rinse fuel tank with clean fresh kerose...

Page 11: ...POWER SOURCE 2017 Pinnacle Climate Technologies Inc Kerosene Forced Air Heater User s Manual 10 14 11 13 8 12 9 30 26 3 16 2 4 6 1 7 22 24 17 18 19 21 30 20 15 41 33 35 36 29 28 5 32 31 25 27 38 37 3...

Page 12: ...21 0510 70 021 0520 70 021 0520 18 Pump Body 70 020 0101 70 020 0101 70 020 0101 70 020 0401 70 020 0401 19 Rotor Kit 70 022 0100 70 022 0100 70 022 0100 70 022 0200 70 022 0200 20 End Pump Cover 70 0...

Page 13: ...If Pinnacle Climate Technologies Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other expres...

Page 14: ...1 Industrial Blvd 101 Sauk Rapids MN 56379 USA Toll Free 866 676 1989 Fax 320 251 2922 Web www remingtonheater com Email info pinnacleclimate com 2017 Pinnacle Climate Technologies Inc...

Reviews: