background image

 
 

HUNTER-PRO RSA Intruder Alarm System - User Manual for LCD keypads 

 

7

 

 

 

 

CH. 2: 

 

  

KEYPADS 

 
HUNTER-PRO RSA works with PIMA’s LCD keypads: RXN-400 and RXN-410, 
especially designed for maximum simplicity, durability and decorative 

design. The keypad is used for arming, disarming and programming the 
system as well as displaying time and date, system status information, 

events and defaults, memory log and more. 

Both keypad models are identical, except for the size of the display screen: 

 

RXN-410: Large screen 23 x 97 mm 

 

RXN-400: Small screen 15 x 60 mm 

 

Up to eight keypads can be connected to the system 

1 JAN 04  12:40

RXN-410

 

Drawing 1- PIMA LCD RXN-410 keypad with PIMA Display 

System display: 

Date & Time 

ARM LED 

(green) 

Fault LED 

(red) 

System display: 

Zones Status 

Num & Function 

keys 

Navigation & 
Programming 

keys

Summary of Contents for HUNTER-PRO RSA

Page 1: ...UNTER PRO RSA Intruder Alarm System LCD Keypads User Guide PIMA Electronic Systems Ltd 5 Hatzoref Street Holon 58856 Israel 972 3 5587722 972 3 5500442 support pima alarms com http www pima alarms com...

Page 2: ...a retains the right to modify this manual or any part thereof from time to time without serving any prior notice of such modification Please read this manual in its entirety before attempting to progr...

Page 3: ...Disarming via Keypad 12 3 2 Arming Disarming with Key 16 3 3 Disarming the System 16 3 4 Remote Control via Touch tone Phone 17 CH 4 PROGRAMMING OPERATION 20 4 1 Programming Codes 20 4 2 Programming T...

Page 4: ...t allow it to befit the customer s individual needs and yet remain easy to program and use both by the customer and the technician Therefore it is important to read this manual from cover to cover in...

Page 5: ...yle Status of all 32 zones is displayed simultaneously Four Subscriber dialing numbers with optional voice message Four Monitoring Stations phone numbers PIMA unique Integrated Digital Communicator te...

Page 6: ...ss until confirmation beep is heard Press this key at any programming stage in order to return to root screen Default Master Code 5555 Enabled User Code A code enabled by Master Code to enter User Men...

Page 7: ...well as displaying time and date system status information events and defaults memory log and more Both keypad models are identical except for the size of the display screen RXN 410 Large screen 23 x...

Page 8: ...displayed in a single screen using signs and abbreviations 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 4 J A N 0 4 P S 0 0 2 2 B _ F _ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Upper Line Display wh...

Page 9: ...reens automatically interchange and display their status in a chronological order 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 4 J A N 0 4 P S 0 0 2 2 T a m p e r 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14...

Page 10: ...ies Temporary bypass of zones Arming the system to mode Home 1 partial arming Fast arming the system to Home 1 mode if enabled by technician Display menu see section Zone Status Display Programming te...

Page 11: ...about authorization levels and how to change them see Programming Codes on page 20 2 3 1 Entering User Menu with Master Code To access the User Menu Master Code User Menu Choose 1 2 Function key see p...

Page 12: ...r events e g fire panic etc It is possible to arm the system with open zones but these zones should be bypassed for the system to be armed see Arming with Open Zones on page 13 3 1 Arming Disarming vi...

Page 13: ...ming with Open Zone s When activating the system with one or more opened zones that are not on the exit route i e exit delayed zones the keypad will produce a fast beep and the display will show Open...

Page 14: ...essage is displayed HOME 1 or HOME 2 according to the pressed key 3 1 5 Fast Arming To quickly arm the system if enabled by technician Full Arming Arming HOME 1 Arming HOME 2 NOTE Exit delays in HOME...

Page 15: ...ser s number X6 Add keyfob ENTER NEXT END 1 2 3 4 5 6 7 8 9 10 11 1 2 13 14 1 5 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Add keyfob Activate device 1 2 3 4 5 6 7 8 9 10 11 1 2 13 14 1 5 16 1...

Page 16: ...5 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 wait for confirmation Device deleted ENTER NEXT END 1 2 3 4 5 6 7 8 9 10 11 1 2 13 14 1 5 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 to exi...

Page 17: ...any touch tone telephone including cellular phone The system can be controlled from the moment there is communication between the system and the telephone whether the system called the telephone or w...

Page 18: ...ing the system as set by the technician 3 4 1 MODE A One touch control 5 Execute command by pressing a key on the phone The following table includes system s commands by phone keys Phone key Function...

Page 19: ...der no 2 output 33 Expander no 3 output NOTE During communication time between system and telephone the following display will appear Other keypad in use If the system receives no command within a min...

Page 20: ...HUNTER PRO RSA has a code control feature that does not allow entering identical codes For example if one of the user or master codes is programmed as 1010 any attempt to program a new code as 1010 o...

Page 21: ...numbers etc HUNTER PRO RSA holds up to 24 different User Codes 4 to 6 digits each See Entering User Menu on page 11 for a description on how to access the User Menu with User Code NOTE A name can be p...

Page 22: ...Entering User Name User 1 ENTER NEXT END Use and to reach designated user press user s number User Name ENTER NEXT END User Name 1 User 1 Enter name How to Select and Enter Characters Each numeric cod...

Page 23: ...disarming will enter the memory along with the user name date and time see section Memory Display on page 33 The order of the ABC letters is identical to that in a cellular phone 1 A B C 2 D E F 3 Ca...

Page 24: ...ve data press User Access Bar parameter letters U User can program User Codes T User can program phone numbers C User can program time and date M User can view the Memory Log B User can bypass zones K...

Page 25: ...artitions all users are assigned by default to all partitions 4 1 3 Programming Door Code This code controls the system s relay for opening and closing electric gates activating video cameras and more...

Page 26: ...disarm the system if armed and trigger the Silent Alarm sending a duress signal to the security station without activating the sirens Note the code is between 4 to 6 digits Master Code Enabled User Co...

Page 27: ...ime or after silent time period the system will commence auto arming unless it was armed before that time This feature is valid for all weekdays The system can detect movement in the protected area vi...

Page 28: ...X Time in which the system will be armed HH MM NOTE To cancel Auto Arming the Automatic Arming programming needs to be repeated and the time to be set as 00 00 Press to save programming and move to th...

Page 29: ...mitted via the telephone used by the system The system shall hang up after a minute of not receiving any command Remote Control via Touch tone Phone on page 17 NOTE In case a Voice Unit is connected t...

Page 30: ...e feature enables to control opening closing doors and windows by activating the keypad s buzzer for two seconds each time a door window is opened This feature is especially useful when there are smal...

Page 31: ...tem s response to a panic event for example calling the Monitoring Station or your private telephone number activate a relay video camera activate siren etc Consult your installer about programming th...

Page 32: ...r is cancelled no sounds will be produced from this specific keypad 4 10 Bypassing Zones This feature is used for temporary bypassing of zone s for example in case of a fault Master Code Enabled User...

Page 33: ...10 next events in one key press Press to jump 10 events back in one key press 4 11 2 Memory Log Display Includes arming and disarming along with user name and code and any zones bypassed prior to armi...

Page 34: ...and seven types of zone status display The two system status displays are Fast Display All the zones and their status appear in a single screen Scrolling Display A detailed description of the zones a...

Page 35: ...ser Code long press User Code Display Type Fast Zn Display Display Type Scan Open Zones Display Type Disable Zn Disp Display Type All Zones Display Type Display Bypass Z Display Type Display Soak Zn D...

Page 36: ...o disappear If the fault indication persists longer then one day the back up battery should be replaced Mains Fault Usually appears during a power failure If other electrical appliances in the house a...

Page 37: ...PRO motherboard Call the technician GSM Unit Fault GSM unit not connected operating properly Call the technician GSM Link Fault Bad reception or blocking of GSM channel Call the technician GSM Card F...

Page 38: ...HUNTER PRO RSA Intruder Alarm System User Manual for LCD keypads 38 5 1 Zones Names Zone No Partition No Zone Name 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16...

Page 39: ...HUNTER PRO RSA Intruder Alarm System User Manual for LCD keypads 39 Zone No Partition No Zone Name 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32...

Page 40: ...P N 4410211 Rev A Sep 2005...