Captain 6 Installation Guide
29
5.4
System configuration
The System configuration is a set of 8 consecutive screens that includes various
parameters for configuring the CAPTAIN 6 alarm system.
5.4.1
Config 1
Technician code
Select:
CPTN XX en 6.10
System config.
:
ENTER/NEXT/END
PPTPTB Phone
+----+ Config 1
set the parameters
See section 3.2.4 for programming instructions of the parameters bar.
Par.
Onscreen When setting to “+”
P
Phone
The control panel is connected to telephone line.
P
TrgTst-P
While the system is armed, the control panel will send a TEST report by the
phone, in response to 2 phone rings.
T
TrgTst-T
While the system is armed, the control panel will send a TEST report by the
Radio, in response to 2 phone rings.
P
AutTst-P
The system will send a periodic TEST report by the phone. See section
T
AutTst-T
The system will send a periodic TEST report by the Radio. See section
B
AutoBYpS A zone that triggers the alarm 3 consecutive times will automatically be
bypassed until the system is disarmed.
5.4.2
Config 2
Technician code
Select:
CPTN XX en 6.10
System config.
:
ENTER/NEXT/END
X2
TDZBRT DialTnBp
-----+ Config 2
set the parameters
See section 3.2.4 for programming instructions of the parameters bar.
Par.
Onscreen
When setting to “+”
T
DialTnBp
The system will not wait for a dial tone before dialing.
This is useful for “noisy” telephone lines
D
Dlayed On
Arming the system will be delayed until a confirmation
message is received from the Monitoring Station
The message “Message received” will then be displayed on
the LCD keypads
Z
Zone Disp
While the system is armed, LCD keypads will display the
zone status
LED keypads display open zones regardless of the
system state
B
BZR-ALARM
The keypad’s Chime will sound beeps when the alarm is triggered
R
RST BY ZN
“+”: The control panel will report "restore" when the zone
is closed.
“-”: The control panel will send Restore report after siren
time ends.
Do not enable this parameter when using the PAF format
ENTR
ENTR
ENTR