Commissioning
Operating Manual PSENvip RL D P Set
1001641-EN-09
| 74
}
Attach the bracket to the upper tool clamp.
1
Fig.: Adjustment template with bracket
7.3
Adjustment during tool change
The adjustment line is automatically tracked to the tip of the tool. The tracking of the adjust-
ment line is shown on the display.
INFORMATION
Generally you should not have to mechanically realign the transmitter and
receiver during a tool change.
CAUTION!
The manufacturer or operator of the press must ensure safe selection of the
"Adjustment during tool change" operating mode with appropriate meas-
ures.
CAUTION!
The protective equipment must be tested following a tool change ad-
justment!
Use the standardised test piece to perform a function test, see section en-
titled "Function test of the safety device".
7.3.1
Prepare for adjustment during tool change
}
Transmitter and receiver must be exactly aligned to each other and to the centre point of
the upper tool, as described in the section entitled "Initial commissioning".
}
The supply voltage must be present.