Commissioning
Operating Manual PSENvip RL D P Set
1001641-EN-09
| 67
}
The illuminated target area must completely envelop the receiver. If you hold a white
sheet of paper behind the receiver you will be able to see the contours of the receiver
better.
Illuminated target area
Fig.: Receiver illuminated by transmitter
}
If the illuminated target area does not enclose the receiver as shown in the diagram, then
you will need to realign the transmitter
INFORMATION
Carefully align the illuminated target area to the receiver. This will make the
adjustments in the following work stages easier.
7.2.1.5
Tool shapes
The correct adjustment of the upper tool also depends on the tool shape. The tools are di-
vided into tool classes in the
Tool Change
menu.
INFORMATION
You must comply with the tool class information provided in
– Section 7.3 "Adjustment during tool change", "Tool detection" in this
chapter.
– Section entitled "Tool shapes", under "Safety"
– "System Connections" chapter
During initial commissioning, the upper tool should be positioned in a way that corresponds
to the expected tool class.
Two bending lines are available on the PSENvip display for correct alignment of the various
tool types. In the following examples, please note that the maximum width of the respective
tools for the tool class can be achieved when the appropriate bending line is used.
Examples of the correct adjustment of various tool types: