Operating Manual
PSEN op2H Series
17
Special L-brackets are available on request
for installations that require no large
mechanical adjustments during alignment
(see Fig. 13).
Adjustable brackets enable the units to be
inclined by ± 5° and are also available on
request.
Where applications are subject to particularly
strong vibration we recommend the use of
angle brackets with vibration dampers.
The drawing and table below indicate the
recommended fixing points in relation to the
length of the light curtain.
MODEL
L (mm)
A (mm)
B (mm)
C (mm)
PSEN op2H-30-015
212 72
70 -
PSEN op2H-30-030
359 179
90 -
PSEN op2H-30-045
506 286
110 -
PSEN op2H-30-060
653 373
140 -
PSEN op2H-30-075
800 460
170 -
PSEN op2H-30-090
947 547
200 -
PSEN op2H-30-105
1094 654
220 -
PSEN op2H-30-120
1241 841
200
420
PSEN op2H-30-135
1388 988
200
494
PSEN op2H-30-150
1535 1095
220 547
Fig. 13