PSEN op2H-SL Series
Operating Manual PSEN op2H-SL Series
1004304-EN-01
37
Check the safety function of the safety light grid
Procedure
In each of the stated tests, the OSSDs must switch to the OFF state and the OSSD status
LED on the receiver must light up red:
OSSD
.
1. Move the test rod slowly through the protected field (see diagram):
– In the vicinity of the transmitter
– In the vicinity of the receiver
– In the centre of the protected field
2. Place the test rod at rest in a position in the protected field that is considered critical for
the safety assessment results
[1]
Legend
[1] Test rod
Check ambient conditions and installation
}
Correct alignment and attachment
Check the seating of the mounting screws by applying pressure to the edges of the
safety light grid. The OSSD LED
OSSD
on the receiver must not light up red.
}
Safety distance
The safety distance must comply with the requirements in Maintaining the safety dis-
tance.
}
Circumventing the protected field
The danger zone must be secured so that it is impossible to access by circumventing