PSEN op2H-SL Series
Operating Manual PSEN op2H-SL Series
1004304-EN-01
33
Cascaded safety light grid
Use the cables stated in the
Order references for accessories [
51]
.
[1]
[2]
Legend
[1] Connection to master unit, cascading adapter, 5-pin
[2] Connection to slave unit, M12, 5-pin, female socket
1. Install the master unit and slave unit(s). See
Installation [
22]
.
2. Loosen the screws [1] on the cover of the cascading adapter and remove the cover.
[1]
Legend
[1] Fixing screws on the cover of the cascading adapter
3. Connect the 5-pin cascading adapter on the cable PSEN op SL cascading to the cas-
cading adapter on the master unit and the 5-pin female socket to the slave unit.
4. Re-attach the cover of the cascading adapter and tighten both screws to 0,2 Nm.