PSEN ma1.4p-59
Operating Manual PSEN ma1.4p-59
1003594-EN-06
| 7
}
Do not remove the connector's protective cap until you are just about to connect the unit.
This will prevent potential contamination.
Safety switch PSEN ma1.4p-59
The safety switch meets the requirements of EN 60204-1:2006.
The safety switch only complies with EN 60947-5-3:2005 in conjunction with the actuator
PSEN ma1.4-10mm and its approved evaluation devices.
The safety switch should only be connected to the evaluation devices listed under
ments and connection to evaluation devices [
.
Unit features
}
The actuator PSEN ma1.4-10mm belongs to the safety switch.
}
2 safety contacts (reed contacts - N/O)
}
1 auxiliary contact (N/O)
}
Actuator PSEN ma1.4-10mm :
– Assured operating distance: 10 mm
– Assured release distance: 22 mm
}
Operation Magnetic
}
Switching voltage 24 VDC
}
LED to display switch status
}
Design: Square
Function description
If the actuator is within the response range (safety gate closed), the safety contacts and the
auxiliary contact on the safety switch will be closed and the LED will light.
Operate the PSEN ma1.4p-59 in conjunction with the following components:
}
Actuator PSEN ma1.4-10mm (see
}
a connected evaluation device (see
Requirements and connection to evaluation
devices [