PSEN ma1.4p-59
Operating Manual PSEN ma1.4p-59
1003594-EN-06
| 10
Pin assignment
NOTICE
The colour marking for the connection lead only applies for the cable that
Pilz supplies as an accessory
The safety switch is shown in an unoperated condition.
Assignment of
the 8-pin con-
nector
pink
green
white
yellow
brown
blue
red
grey
NC
NC
NOTICE
The auxiliary contact with LED
– May only be operated with a supply voltage of up to 24 VDC with
PNOZ X units
– May not be connected in series with PNOZ X, PNOZelog and
PNOZmulti units
– may
not
be used for safety circuits
Requirements and connection to evaluation devices
For use of PSEN ma1.4p-59 in accordance with DIN EN 60947-5-3 an evaluation device
must be connected.
Connect the PSEN ma1.4p-59
}
either
with a certified Pilz evaluation device
}
or
with an evaluation device with defined properties
Certified Pilz evaluation devices are, for example:
}
PNOZelog for safety gate monitoring
– PNOZ e1p, PNOZ e1.1p, PNOZ e1vp
– PNOZ e5.11p
– PNOZ e6vp, PNOZ e6.1p
}
PNOZpower for safety gate monitoring
– PNOZ p1p, PNOZ p1vp