![Pilz PSEN ma1.4-10 Operating Manual Download Page 19](http://html1.mh-extra.com/html/pilz/psen-ma1-4-10/psen-ma1-4-10_operating-manual_1556984019.webp)
PSEN ma1.4p-59
Operating Manual PSEN ma1.4p-59
1003594-EN-06
| 19
Electrical data
Lowest operating current (Im)
1 mA
Switching voltage
24 V
Internal resistance
10 Ohm
Max. switching current, safety contacts
0,2 A
Max. breaking capacity, safety contacts
5 W
Max. switching current, auxiliary contacts
10 mA
Utilisation category in accordance with EN 60947-1
DC-12
Times
Reaction time (actuator removed)
2 ms
Environmental data
Ambient temperature
Temperature range
-10 - 55 °C
Climatic suitability
In accordance with the standard
IEC 60068-2-30
Humidity
93 % r. h. at 40 °C
Max. operating height above sea level
2000 m
EMC
EN 60947-5-3
Vibration
In accordance with the standard
EN 60947-5-2
Frequency
10 - 55 Hz
Amplitude
1 mm
Shock stress
Acceleration
30g
Duration
11 ms
Airgap creepage
Pollution degree
3
Rated insulation voltage
25 V
Rated impulse withstand voltage
0,33 kV
Protection type
Housing
IP65, IP67
Connector
IP67
Operating distances
Assured operating distance Sao
10 mm
Min. operating distance Somin
0,0 mm
Typical operating distance So
12,5 mm
Assured release distance Sar
22 mm
Typical release distance Sr
16 mm
Repetition accuracy switching distances
6 %
Mechanical data
Actuator 1
PSEN ma1.4-10mm
Typ. Hysteresis
3,5 mm
Min. distance between safety switches
50 mm
Sensor flush installation in accordance with EN
60947-5-2
Yes, follow installation guidelines