PSEN cs4.2a
Operating Manual PSEN cs4.2a
1003575-EN-08
| 36
Mechanical data
Sensor flush installation in accordance with EN
60947-5-2
Yes, follow installation guidelines
Connection type
5 m cable
Cable
Li9Y11Y 8 x 0,14 mm2
Material
Top
PBT
Max. torque setting for fixing screws
0,8 Nm
Dimensions
Height
37 mm
Width
26 mm
Depth
18 mm
Weight of safety switch
205 g
Where standards are undated, the 2016-10 latest editions shall apply.
Technical details actuator
Order no. 540180 - 541180
See below for more order numbers
General
540180
541180
Certifications
CE, TÜV, cULus Listed
CE, EAC (Eurasian), TÜV, cULus
Listed
Sensor's mode of operation
Transponder
Transponder
Coding level in accordance with EN
ISO 14119
High
High
Pilz coding type
fully coded
fully coded
Transponder
540180
541180
Frequency band
122 kHz - 128 kHz
122 kHz - 128 kHz
Environmental data
540180
541180
Ambient temperature
In accordance with the standard
EN 60068-2-14
EN 60068-2-14
Temperature range
-25 - 70 °C
-25 - 70 °C
Storage temperature
In accordance with the standard
EN 60068-2-1/-2
EN 60068-2-1/-2
Temperature range
-40 - 85 °C
-25 - 70 °C
Climatic suitability
In accordance with the standard
EN 60068-2-78
EN 60068-2-78
Humidity
93 % r. h. at 40 °C
93 % r. h. at 40 °C
EMC
EN 60947-5-3
EN 60947-5-3
Vibration
In accordance with the standard
EN 60947-5-2
EN 60947-5-2
Frequency
10 - 55 Hz
10 - 55 Hz
Amplitude
1 mm
1 mm