PSEN cs4.2a
Operating Manual PSEN cs4.2a
1003575-EN-08
| 33
Technical details safety switch
General
Certifications
CE, EAC (Eurasian), FCC, IC, TÜV, cULus Listed
Sensor's mode of operation
Transponder
Coding level in accordance with EN ISO 14119
High
Design in accordance with EN ISO 14119
4
Classification in accordance with EN 60947-5-3
PDDB
Pilz coding type
uniquely coded
Transponder
Frequency band
122 kHz - 128 kHz
Max. transmitter output
15 mW
Electrical data
Supply voltage
Voltage
24 V
Kind
DC
Voltage tolerance
-20 %/+20 %
Output of external power supply (DC)
1 W
Max. switching frequency
3 Hz
Max. cable capacitance at the safety outputs
No-load, PNOZ with relay contacts
400 nF
PNOZmulti, PNOZelog, PSS
400 nF
Max. inrush current impulse
Current pulse, A1
0,58 A
Pulse duration, A1
1 ms
No-load current
20 mA
Inputs
Number
2
Voltage at inputs
24 V DC
Input current range
5 mA
Max. overall cable resistance Rlmax
Single-channel at UB DC
1000 Ohm
Semiconductor outputs
OSSD safety outputs
2
Signal outputs
1
Switching current per output
100 mA
Breaking capacity per output
2,4 W
Potential isolation from system voltage
No
Short circuit-proof
yes
Residual current at outputs
20 µA
Voltage drop at OSSDs
3,5 V
Lowest operating current
0 mA
Utilisation category in accordance with EN 60947-1
DC-12