PSEN cs4.2a
Operating Manual PSEN cs4.2a
1003575-EN-08
| 27
7. Check the adhesive force of the glue after 10 minutes.
The actuator must no move when pressed sideways.
8. Remove the assembly aid from the safety switch and clean the sensing area of the
safety switch.
Procedure actuator PSEN cs4.1 low profile screw
1. Provide the mounting surface with a drill hole for an additional screw connection of the
2. To seal the low profile actuators correctly, it is necessary to prepare the surface to
which the actuator is to be attached.
The surface must be clean, dry and free of grease.
Wipe off any solved grease and contaminations with a new, dry paper cloth.
Clean the surface with 70% isopropanol. Use lint-free paper cloths and change the pa-
per cloths frequently.
The adhesive surface is clean when the paper remains clean.
The cleaned surfaces must be sealed immediately to prevent any new contamination by
dust and fingerprints.
3. Remove the protective foil from the assembly aid and fix it to the sensing area of the
safety switch.
4. Place the actuator into the assembly aid so that the actuator’s covered adhesive sur-
face is on the surface.
Make sure that the actuator’s centre is on the same level as the orientation arrows of
the sensor and in the centre of the sensor.
5. Remove the protective foil from the adhesive foil of the actuator.
Do not touch the adhesive foil after removing the protective foil!
6. Insert the screw into the actuator’s hole and position the screw at the hole on the
mounting surface.
To screw on the actuator, use the supplied plastic M3 countersunk screw.
When using a screw mad from metal the operating distance change, please note the
Warning [