PSEN cs4.2a
Operating Manual PSEN cs4.2a
1003575-EN-08
| 34
Times
Test pulse duration, safety outputs
450 µs
Switch-on delay
after UB is applied
1 s
Inputs typ.
13 ms
Inputs max.
20 ms
Actuator typ.
60 ms
Actuator max.
150 ms
Delay-on de-energisation
Inputs typ.
15 ms
Inputs max.
20 ms
Actuator typ.
40 ms
Actuator max.
260 ms
Risk time in accordance with EN 60947-5-3
260 ms
Supply interruption before de-energisation
10 ms
Simultaneity, channel 1 and 2 max.
∞
Environmental data
Ambient temperature
In accordance with the standard
EN 60068-2-14
Temperature range
-25 - 70 °C
Storage temperature
In accordance with the standard
EN 60068-2-1/-2
Temperature range
-25 - 70 °C
Climatic suitability
In accordance with the standard
EN 60068-2-78
Humidity
93 % r. h. at 40 °C
EMC
EN 60947-5-3
Vibration
In accordance with the standard
EN 60947-5-2
Frequency
10 - 55 Hz
Amplitude
1 mm
Shock stress
In accordance with the standard
EN 60947-5-2
Acceleration
30g
Duration
18 ms
Airgap creepage
Overvoltage category
III
Pollution degree
3
Rated insulation voltage
75 V
Rated impulse withstand voltage
0,8 kV
Protection type
Housing
IP6K9K