Wiring

Operating Manual PMI v704e/v707e
1003980-EN-02

26

6.2.2

Connection example

[1]

[2]

[3]

[3]

[5]

[6]

PMI v704e

PMI v707e

Fig.: Connection example

6.2.3

USB socket

The USB socket (screen/housing) is connected directly (not capacitive) to ground (GND). If
a GND connection is to be created to a remote point (e.g. via an USB-RS485 converter or
similar), an unlimited and possibly damaging equalising current can flow over the shield. In
this case, the interface should be galvanically isolated.

Summary of Contents for PMI v704e

Page 1: ...PMI v704e v707e Operating Manual 1003980 EN 02 Operator terminals ...

Page 2: ...enta tion will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Internet on the Pilz homepage Pilz PIT PMI PNOZ Primo PSEN PSS PVIS SafetyBUS p SafetyEYE SafetyNET p the spirit of safety are registered and protected trademarks of Pilz GmbH Co KG in some countries SD means...

Page 3: ...gulations 12 3 2 1 Use of qualified personnel 12 3 2 2 Warranty and liability 12 3 2 3 Disposal 12 3 3 Unit specific safety regulations 12 3 3 1 Installation site 12 3 3 2 Measures to protect against interference 13 3 3 3 Supply voltage 13 3 3 4 Operation 13 3 3 5 Maintenance 13 Section 4 Function description 14 4 1 Device properties 14 4 2 Side view 15 4 2 1 PMI v704e 15 4 2 2 PMI v707e 16 Sectio...

Page 4: ...26 Section 7 Commissioning 27 7 1 Setup of the device with the PMI Manager 27 7 1 1 Network settings 28 7 1 2 Configuration 29 7 1 3 Settings for the PASvisu server 31 7 1 4 Licence information 32 7 1 5 Exit PMI Manager 33 Section 8 Firmware update 34 Section 9 Care and Maintenance 35 9 1 Cleaning the touchscreen 35 Section 10 Technical details 36 Section 11 Order reference 38 11 1 Product 38 11 2...

Page 5: ...NGER This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates preventive measures that can be taken WARNING This warning must be heeded It warns of a hazardous situation that could lead to serious injury and death and indicates preventive measures that can be taken CAUTION This refers to a hazard that can lead to a less ...

Page 6: ...ble e your reply address and your E mail address if possible Pilz can charge a fee for the data medium and for sending The request for the source code must be received 3 years at the latest after the receipt of the relevant GPL or LPG Irrespective of this period we will send you a complete machine readable copy of the source code as long as Pilz offers spares or technical support for this device P...

Page 7: ...ator terminal that is used to operate and monitor technical processes 2 1 1 Unit features Capacitive touchscreen Character set Unicode Memory 512 MB DDR SDRAM 2 GB Flash 1 Ethernet interface 1 USB Host interface 2 0 Type A Capacitor buffered real time clock Pre installed software Pilz visualisation software ...

Page 8: ...Overview Operating Manual PMI v704e v707e 1003980 EN 02 8 2 2 Front view 2 2 1 PMI v704e 1 Fig Front view PMI v704e Legend 1 Touchscreen see Technical details 36 ...

Page 9: ... EN 02 9 2 2 2 PMI v707e 1 Fig Front view PMI v707e Legend 1 Touchscreen see Technical details 36 2 3 Scope of supply Operator terminal 1 clamp frame for installation 1 set of screws and connectors Projection stand in the shape of the packaging carton ...

Page 10: ...anual PMI v704e v707e 1003980 EN 02 10 2 4 Accessories 1 Fig Top hat rail for PMI v704e Legend 1 Top hat rail for installation in the control cabinet see order data 38 NOTICE The top hat rail may only be used for PMI v704e ...

Page 11: ...n industrial environment The product may cause interference if installed in other environments If installed in other environments measures should be taken to comply with the applicable standards and directives for the respective installation site with regard to in terference 3 1 1 Supported hardware and software PNOZmulti base units from the following versions Configurable safety systems PNOZmulti...

Page 12: ... the generic and specialist standards applicable to the spe cific application 3 2 2 Warranty and liability All claims to warranty and liability will be rendered invalid if The product was used contrary to the purpose for which it is intended Damage can be attributed to not having followed the guidelines in the manual Operating personnel are not suitably qualified Any type of modification has been ...

Page 13: ...tar form A cable cross section of at least 1 5 mm should be used Connections should be kept as short as possible 3 3 3 Supply voltage The supply voltage must be 24 V DC CAUTION Safe electrical isolation must be ensured for the external power supply gen erating the 24 V voltage supply Failure to do so could result in electric shock Power supplies must conform to DIN VDE 0551 EN 60742 and EN 50178 3...

Page 14: ...processes can be shown on the display and directly influ enced via the touchscreen An Ethernet interface is available for the transfer of data e g diagnostic data and for communication with other subscribers The device is fitted with a real time clock that is capacitor buffered so allowing it to run for approx 14 days without an external power supply The capacitor is automatically charged during o...

Page 15: ...Function description Operating Manual PMI v704e v707e 1003980 EN 02 15 4 2 Side view 4 2 1 PMI v704e 1 2 3 Fig Side view PMI v704e Legend 1 USB Host 2 Ethernet interface 100 BaseTX 3 Supply voltage ...

Page 16: ...Function description Operating Manual PMI v704e v707e 1003980 EN 02 16 4 2 2 PMI v707e 1 2 3 Fig Side view PMI v707e Legend 1 USB Host 2 Ethernet interface 100 BaseTX 3 Supply voltage ...

Page 17: ...hould refer to any guidelines laid down by the plant manufacturer or operator 5 1 1 Installation site and unit surroundings Keep as large a distance as possible between the system and any electromagnetic fields particularly when frequency converters are nearby To avoid the build up of heat a distance of 10 cm 3 94 should be kept free all round the unit Protect the system from direct sunlight and d...

Page 18: ...MI v704e PMI v707e b1 mm h1 mm 135 5 315 95 3 740 200 7 874 142 5 591 b2 mm h2 mm t mm 116 6 4 591 77 6 3 055 29 1 142 182 7 165 124 4 882 43 1 693 b3 mm h3 mm 117 1 4 606 0 039 78 1 3 071 0 039 183 1 7 205 0 039 125 1 4 921 0 039 h t Dimensions without connections b2 h2 Dimensions without press in frame Allow extra for hardware connections ...

Page 19: ...thickness may be maximum 5 mm To avoid a build up of heat a distance of a 10 cm 3 94 should be maintained all round the system Note the information given for the ambient and operating temperatures in the Technical details 36 IP65 protection can only be guaranteed when the device s fixing screws are tightened with a torque of 1 Nm the gasket is not damaged the mounting position is vertical the Pilz...

Page 20: ...Installation Operating Manual PMI v704e v707e 1003980 EN 02 20 5 4 Installation 5 4 1 PMI v704e Fig Installing PMI v704e ...

Page 21: ...Installation Operating Manual PMI v704e v707e 1003980 EN 02 21 Fig Installing PMI v704e with top hat rail ...

Page 22: ...Installation Operating Manual PMI v704e v707e 1003980 EN 02 22 Fig Strain relief for Ethernet and USB cables PMI v704e ...

Page 23: ...Installation Operating Manual PMI v704e v707e 1003980 EN 02 23 5 4 2 PMI v707e Fig Installing PMI v707e Fig Strain relief for Ethernet and USB cable PMI v707e ...

Page 24: ...withstand 60 75 C for the supply voltage maximum torque setting 0 5 0 6 Nm 6 1 1 Shielding Connect the network cable shields with low impedance to earth Use shielded data lines only Use equipotential bonding cables Perform a potential isolation Data line shielding should be connected to a cable shield bus bar The connection between the cable shield bus bar and the control cabinet system should be ...

Page 25: ...0 EN 02 25 6 2 Connecting the unit 6 2 1 Supply voltage The connection for the 24 V DC supply is located on the side of the housing 1 2 Fig Layout of supply voltage connector 1 0 V 2 24 V DC UL requirement Use a 24 VDC power supply isolating source ...

Page 26: ...le 6 2 3 USB socket The USB socket screen housing is connected directly not capacitive to ground GND If a GND connection is to be created to a remote point e g via an USB RS485 converter or similar an unlimited and possibly damaging equalising current can flow over the shield In this case the interface should be galvanically isolated ...

Page 27: ...ay of several seconds between switch on and the unit being ready for operation 7 1 Setup of the device with the PMI Manager Fig Start screen PMI Manager After starting the PMI you can make basic settings for the device in the PMI Manager To do this touch the button within 5 seconds The interface is only available in English ...

Page 28: ...80 EN 02 28 7 1 1 Network settings After starting the following view will open where you can configure all the required network settings Fig Network settings When you touch a field a key field will open for entering the address Fig Entry network settings ...

Page 29: ...view will open Fig Configuration The host name is entered automatically and it can be changed You can use a time server To do this touch the empty field behind Use NTP Time Service You can select whether you want to enter an IP address in IPv4 format or an URL e g the address of the Physikalisch Technische Bundesanstalt ptbtime1 ptb de Fig Use time server ...

Page 30: ...rating Manual PMI v704e v707e 1003980 EN 02 30 The local time will be adapted automatically as the system time Touch the button to change the date or time Enter the time in 24 hour format hh mm ss Fig Set time and date ...

Page 31: ...the sidebar touch the button to make further settings for the PASvisu server You have the option to use a local PASvisu Server To do this enter the IP address of PASvisu Server in IPv4 format Default setting IP address 127 000 000 001 Server HTTP port 40856 Server WS port 40857 Fig Settings PASvisu Server ...

Page 32: ...Commissioning Operating Manual PMI v704e v707e 1003980 EN 02 32 7 1 4 Licence information In the sidebar touch the button to display the licence information Fig Licence information ...

Page 33: ...anager Then the following view will open Fig Exit PMI Manager Touch the button Apply to confirm all the entries and to restart the device Touch the button Discard to reject the changes and to start the PASvisu project Touch the button Cancel to return to the settings Further information on PASvisu can be found in the PASvisu online help ...

Page 34: ...ick into the PMI v704e v707e and start the PMI v704e v707e 3 The Firmware update window will appear Please note that the PASvisu project is de leted during a firmware update Click Yes to start the firmware update or Cancel to can cel the firmware update 4 If you click Yes a window will appear stating that the device must not be switched off during the firmware update and that the USB stick must no...

Page 35: ...een at regular intervals Use a damp cloth to do this NOTICE Make sure the unit is switched off before cleaning it This prevents you from accidentally triggering functions when you touch the touchscreen Cleaning agents Only use water and washing up liquid or window cleaner to dampen the cloth Never use aggressive solvents or abrasive cleaning agents ...

Page 36: ...2 MB 512 MB Real time clock yes yes USB interface 266704 266707 Number of USB Hosts 1 1 Type of USB host interface USB 2 0 Type A USB 2 0 Type A Ethernet interface 266704 266707 Transmission rate 100 MBit s 100 MBit s Environmental data 266704 266707 Ambient temperature Temperature range 0 50 C 0 50 C Storage temperature In accordance with the standard EN 60068 2 1 2 EN 60068 2 1 2 Temperature ran...

Page 37: ... 1g 1g Shock stress In accordance with the standard EN 60068 2 27 EN 60068 2 27 Acceleration 15g 15g Duration 11 ms 11 ms Protection type In accordance with the standard EN 60529 EN 60529 Housing IP20 IP20 Front IP65 IP65 Mechanical data 266704 266707 Dimensions Height 95 mm 142 mm Width 135 mm 200 mm Depth 36 3 mm 50 3 mm Weight 348 g 944 g Where standards are undated the 2018 01 latest editions ...

Page 38: ...uct type Features Order no PMI v704e Operator terminal 480 x 272 pixel resolution ca pacitive touchscreen 266 704 PMI v707e Operator terminal 800 x 480 pixel resolution ca pacitive touchscreen 266 707 11 2 Accessories Product type Features Order no DIN rail adapter TSH 35 DIN top hat rail TSH 35 266 103 ...

Page 39: ...fetyNET p THE SPIRIT OF SAFETY are registered and protected trademarks of Pilz GmbH Co KG in some countries We would point out that product features may vary from the details stated in this document depending on the status at the time of publication and the scope of the equipment We accept no responsibility for the validity accuracy and entirety of the text and graphics presented in this informati...

Reviews: