6-3
6.3
Shielding
6
Wiring
6.3
Shielding
6300
Shielding
6-
Verdr_Schirmung_S1
Forimmunityreasons,thesignallinesforthedigitalinputs,outputsand
encodermustbeshielded:
Allshieldedcablesaretobeattachedatbothendstotheshieldter-
minalsprovidedorshouldbeconnectedtotheconnectorhousing.
Usecableswithabraidedshield,withaminimumcoverageof80%.
Anyinterruptionstotheshieldinge.g.atterminals,shouldbebridged
atlowimpedanceoverawidearea.
Allconnectorsorsocketsshouldbefastenedwithscrewstoensure
ample,conductivecontactbetweenthebraidedshieldandthefront
plate.
Theshieldfortheencoder'ssignallinesisconnectedtotheconnector
housings.
Theshieldsforthedigitalinputsandoutputsshouldbeconnectedtothe
frontoftheservoamplifier,asshowninthediagrambelow.
][Verdr_Schirm_Front
Removetheoutercablesheathand
thebraidedshieldtotherequiredwire
length.Securethewireswithacable
tie.
Removetheoutercablesheathtoa
lengthofapprox.30 mm.Becareful
nottodamagethebraidedshield.
Stripallthewiresandfitendferrules.
Usethecabletiestoattachthecable
totheshieldingplateontheside(1)or
bottom(2)oftheservoamplifier.
Pressthecable'sbraidedshieldfirmly
againsttheshieldingplateontheser-
voamplifierusingacabletie.
Alternativelyyoucanusetheshielded
connectionterminals(3)(availableas
anaccessory).Thesehookintothe
bottomshieldingplateandguarantee
optimumcontactbetweentheshield
andtheshieldingplate.
(1)
(2)
(3)