Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
4-1
4
Function description
4
4000
Function description
Function description
4-
Funktionsbeschreibung_allgemein_BAWS
The operating mode selector switch enables you to switch between 5
different operating modes. Operating modes OM1 ... OM4 plus a special
service mode (OM5.)
For OM1 ... OM4, one button each is available. For the special service
mode (OM5), button 1 must be operated for a certain time period (see
Time monitoring -> Operating time). Each button is assigned a moni-
tored semiconductor output. Operating the button changes the semi-
conductor output from low to high. The semiconductor outputs must be
evaluated via a safety control system. The operating mode selector
switch guarantees that only one of the semiconductor outputs is high at
any one time.
Block diagram:
User Interface
RFID
Receiver
=
=
A1
A2
OM 1
Actuator
OM 2
OM 3
OM 4
OM 5
SI0
SI1
SI2
SI3
IDsync
IDclock
IDo0
IDo1
IDi0
IDi1
Input
Power