Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
8-1
8.1
Technical details
8
Technical details
8
1000
Technical details
Technical details
8-
8.1
Technical details
1100
Technical details
8-
][Technische Daten BAWS
Technical details
Sensor's mode of operation
Transponder
Typ. operating distance
5.0 mm
Electrical data
Supply voltage U
B
DC
24 V
Voltage tolerance
-15 %/+10 %
Residual ripple DC
20 %
Power consumption at U
B
2.5 W
Times
Switch-on delay after applying U
B
1.0 s
Supply interruption before de-energisation
20 ms
Switchover delay t1
50 ms
Operating time of button 1 ... 4
50 ms ... 5 s
Operating time of Service button
5 s ... 10 s
Outputs operating modes
Number of positive-switching single-pole semiconductor
outputs
5
Switching current per output
20 mA/24 V
Short circuit-proof
yes
Residual current at "0"
0.3 mA
Signal level at "1"
UB - 3.5 V DC at 20 mA
Status display
LED
Signal outputs
Number
8
Switching current per output
20 mA/24 V
Short circuit-proof
yes
Residual current at "0"
0.3 mA
Signal level at "1"
UB - 3.5 V DC at 20 mA
Inputs
Number
2
Voltage and current at Input circuit DC: 24 V DC
1.5 mA
Galvanic isolation
no
Signal level at "0"
-3 - +5 V DC
Signal level at "1"
15 - 30 V DC
Safety-related characteristic data
PL in accordance with EN ISO 13849-1: 2006
PL d (Cat. 3)
Category in accordance with EN 954-1
Cat. 3
SIL CL in accordance with EN IEC 62061
SIL CL 2
PFH in accordance with EN IEC 62061
5.75E-09
SIL in accordance with IEC 61511
SIL 2
PFD in accordance with IEC 61511
3.19E-04
T
M
[year] in accordance with EN ISO 13849-1: 2006
20
Environmental data
Vibration to EN 60068-2-6
Frequency
10 - 55 Hz
Amplitude
0.35 mm
EMC
EN 60947-5-1
Climatic suitability
DIN IEC 60068-2-3
Airgap creepage in accordance with EN 60664-1
Overvoltage category
II
Pollution degree
2
Rated insulation voltage
60 V