Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
6-1
6.1
Terminal Configuration
6
Wiring
6
6000
Wiring
Wiring
6-
6.1
Terminal Configuration
6100
Terminal Configuration
6-
Klemmenbelegung BAWS
Connect the supply voltage X1 (A1/A2). The power supply must meet
the regulations for extra low voltages with safe separation (SELV,
PELV).
Connect the semiconductor outputs X1 (OM1 ... OM5) to a safety sys-
tem that supports a safe 1 from n evaluation.
Connect the signal outputs X2 (SI0 ... SI3) to a control system that
supports evaluation of the status information.
Connect the interface X2 (signal outputs IDsync, IDclock, IDo0, IDo1
and inputs IDi0 and IDi1) to a control system that supports the down-
load of the Key ID number.
Functional earth connection.
INFORMATION
The connection terminals are not supplied with the unit.