INFORMATION
This gives advice on applications and provides information on special fea
tures.
Safety
Intended use
The safety gate system meets the requirements in accordance with
}
EN 602041:2006
}
EN 6094753:2005: PDFM with the corresponding actuator PSEN sl1.0
or PSEN
sl1.0fm (see
Technical details: System with normal actuator [
22]
,
Technical detail:
System with freemoving actuator [
25]
, under mechanical data)
}
EN 62061:2005: SIL CL 3
}
EN ISO 138491:2008: PL e and Cat. 4
}
The safety switch may only be used with the corresponding actuator (see
Technical de
tails: System with normal actuator, [
22]
,
Technical detail: System with freemoving
actuator [
25]
, under mechanical data).
The safety level PL e (Cat. 4 )/SIL CL 3 is only achieved if
}
the safety outputs use 2channel processing.
The following is deemed improper use in particular:
}
Any component, technical or electrical modification to the product
}
Use of the product outside the areas described in this manual
}
Use of the product outside the technical details (see chapter entitled "Technical De
tails").
NOTICE
EMCcompliant electrical installation
The product is designed for use in an industrial environment. The product
may cause interference if installed in other environments. If installed in other
environments, measures should be taken to comply with the applicable
standards and directives for the respective installation site with regard to in
terference.
INFORMATION
The magnet surface and counterplate may heat up. When installing, make
sure that heat dissipation is guaranteed.