Teaching in the actuator for the first time:
The first corresponding actuator to be detected by the safety switch (see Technical details:
System with normal actuator [
22]
,
System with freemoving actuator [
25]
, under
mechanical data) is automatically taught in as soon as it is brought into the response range.
To teach in a new actuator:
}
The actuator that is to be taught in must be brought into the safety switch's response
range as the only transponder. As soon as the actuator is detected, the "Safety Gate"
LED switches to a yellow flashing light.
}
After 20 s has elapsed, the "Safety Gate" LED switches to quick yellow flashes. Trigger
a system reset in the next 120 s by interrupting the power supply.
}
When the device is switched back on, the learning procedure is complete and the num
ber of permitted additional learning procedures is reduced by 1.
}
A maximum of 8 learning procedures are possible.
NOTICE
The actuator must not be removed during the learning procedure.
INFORMATION
This actuator cannot be retaught on the same safety switch.
PSEN sl1.0n 2.2
The first corresponding actuator to be detected by the safety switch (see Technical details:
System with normal actuator [
22]
,
System with freemoving actuator [
25]
, under
mechanical data) is automatically taught in as soon as it is brought into the response range.
NOTICE
No other actuator may be taught in once this actuator has been taught.
Installation
}
When installing make sure you comply with the requirements of DIN EN 1088.
}
The safety gate system can be installed on left or righthinged swing gates or on sliding