Connection diagram, single connection
Actuator
Receiver
Evaluation device
24 V
0 V
A1
A2
12
22
I1 (FS)
I2 (FS)
A1
A2
S31
O1 (ST)
FS: Failsafe
ST: Standard
Connection to Pilz evaluation devices
The safety switch PSEN sl1.0n 1.1/2.1/2.2 can be connected to Pilz evaluation devices, for
example. Make sure that an evaluation device is selected that can evaluate OSSD signals
through two channels.
Suitable Pilz evaluation devices are, for example:
}
PNOZelog for safety gate monitoring
}
PNOZpower for safety gate monitoring
}
PNOZsigma for safety gate monitoring
}
PNOZ X for safety gate monitoring
}
PNOZmulti for safety gate monitoring
Configure the switch in the PNOZmulti Configurator with switch type 3.
}
PSS for safety gate monitoring with standard function block SB064, SB066 or
FS_Safety Gate
The correct connection to the respective evaluation device is described in the instructions
for the evaluation device. Make sure that the connection is made in accordance with the
specifications in the instructions for the selected evaluation device.
The connections to two evaluation devices are shown on the following pages, by way of ex
ample:
}
PNOZ s3 and
}
PNOZmulti