PSEN sl1.0n 1.1/2.1/2.2
Operating Manual PSEN sl1.0n 1.1/2.1/2.2
22174EN03
19
Remove the sensor and tighten screw (c).
Align the sensor to the actuator and tighten the screws.
Adjustment
}
The stated operating distances (see Technical details:
System with normal
actuator [
22]
,
System with freemoving actuator [
25]
, under mechanical data)
only apply when the safety switch and actuator are installed facing each other in paral
lel. Operating distances may deviate if other arrangements are used.
}
Note the maximum permitted lateral and vertical offset (see
Lateral and vertical
offset [
10]
).
Operation
Check the function of the safety switch before commissioning.
Any deviations from the properties and functions described in these operating in
structions can lead to hazardous situations.
CAUTION!
Contaminated surfaces can reduce the holding force of the electromagnet.
Make sure that the contact surfaces are clean.
Status indicators:
}
"Power / Fault" LED illuminates green: The unit is ready for operation
}
"Safety Gate" LED lights up yellow: Actuator is within the response range
}
"Lock" LED lights up green: Magnetic guard locking device active
}
"Input" LED lights up yellow: The unit is ready for operation