GENERAL
2-12
/ Husky 12 Foam System
© 2017 Pierce Manufacturing Inc. All Rights Reserved.
2-2.4
Control Head & Display
The foam system is controlled by a foam system control head/display module that contains the programming to
actuate the appropriate valves, direct the hydraulic fluid, and control the injection rate of the foam. All components
plug into this module and are what actually control the system. The user interfaces the foam system through this
module. If replaced, the system calibration must be checked.
The control head directs a microprocessor, which receives input from the system’s water flowmeter while also
monitoring the position of the foam concentrate pump. The microprocessor compares the values of the water flow
versus the position/rate of the foam pump, to ensure the proportion rate is accurate.
Figure
2-15:
Control Head & Display
OM130_20, 1553, 1554, 1555
The Husky 12 control panel is located on the main pump panel and includes six operating buttons: System On/Off,
Page, Foam Prime, Enter, Arrow Up, Arrow Down. The display is a 4.3 diagonally measured color, LCD screen.
System power is indicated by a green LED; the foam pump operating is indicated by a green LED.
The foam system can be turned on or off from most any screen, you do not have to be at the home screen to turn
the system on and off.
Information displayed on the LCD screen includes: mode of operation and various setup or information displays. If
the foam system is turned OFF, the display functions as a flowmeter.
The percent of injection has presets for class A and class B foam. These presets can be changed at the fire
department as desired. The percent of injection can be easily changed at the scene to adjust for changing demands.
The modes of operation are: Class A Foam, Class B Foam (optional), Draft Class A, Draft Class B, Prime, Flush,
Tank A Fill (optional), Tank B Fill (optional), Manual, and Set-up. Pressing the PAGE button on the display allows
the user to select the option to from choose a foam class. Detailed instructions on the operation of each mode can
be found in
.