Husky 12 Foam System
/ 2-5
GENERAL
The Hydraulic Cooler is an oil-to-water type heat exchanger. It takes water directly from the water pump to cool the
closed loop hydraulic system. The cooling water is then returned to the water pump suction while the cooled
hydraulic oil is returned to the hydraulic tank. The hydraulic cooler allows for continual operation of the Husky 12
hydraulic system.
2-2.1e
Hydraulic Manifold Block
Figure
2-5:
Hydraulic Manifold Block
1005
The Hydraulic Manifold Block assembly is a manifold block that controls the direction of the hydraulic oil flow in the
system. The manifold block consists of the machined block, a hydraulic compensating valve, an internal hydraulic
shuttle valve, a hydraulic relief valve, hydraulic pressure test port and the hydraulic proportional valve.
2-2.2
Foam Supply System
The Foam Supply System stores, pumps and distributes the foam concentrate to the foam/water discharges by use
of a foam concentrate tank, foam tank shut-off valve, auxiliary foam inlet, in-line foam strainer, foam pump, check
valve and foam injection manifold.
2-2.2a
Foam Concentrate Tank
The Foam Concentrate Tank is designed to provide on-board storage of foam concentrate. Design features shall
include: construction compatible with foam concentrates, foam tank drain valve, expansion dome with locking fill
hatch and pressure/vacuum vent. The expansion dome allows for changes in foam concentrate volume due to
variations in temperature. Foam concentrate level shall be maintained at the one-third full mark in the expansion
dome at a minimum to reduce the air to foam concentrate interface. The pressure vacuum vent automatically
balances internal foam tank pressure under both suction and filling operations. It is recommended that a cleanable
foam concentrate level unit be installed in the storage tank. The control head will display a warning message when
the foam tank being used is below one quarter tank.
Forward Plug
Hydraulic
Relief Valve
Reverse Plug
Not shown: P1 pressure
test port (on side of
hydraulic block)