Resin Calculator
Use the resin calculator to determine how much resin will be needed to complete all necessary
coats. Refer to the chart below for recommended number of coats. The resin calculator can be
downloaded from the
minimum of 4 coats to be applied when
the pipe is going to be cleaned using
High Pressure Water Jetting .
Maximum Water Jetting Pressure is
2600 PSI or 180 Bar.
A minimum of 3 coats need for abrasion
resistance.
STEP 1
Before you begin preparing the resin for application, verify the following:
(A)
The Mini Miller and Pump are ON.
(B)
The Speed of the Mini Miller is set to 950 to
1100 rpm (speed dial 2
-
3).
(C)
The Speed of the Pump is set to full speed.
(D)
The
Pump is set to rotate clockwise.
SAVE ALL WARNINGS AND INSTRUCTIONS FOR FUTURE REFERENCE
PREPARING THE RESIN cont.
Pipe diameter
Number of Coats
(Corrosion Resistance)
Number of Coats
(Semi Structural)
DN32 (1¼
”)
2
2
DN40 (1½
”)
2
2
DN50
(2”)
2
2
DN70
(3”)
2
2
DN100
(4”)
2
3 to 4
DN150
(6”)
2 to 3
4 to 5