background image

LES FOURS PICARD INC. / PICARDS OVENS INC.

240, blvd Industriel

St-Germain de Grantham

(Qc) J0C 1K0

Tél: (819) 395-5151

Fax: (819) 395-5343

Internet: www.picardsoven.com

QUANTITÉ:

(QUANTITY)

DATE:

(AA/MM/JJ)

(YY/MM/DD)

NO° D'ASSEMBLAGE:

(ASSEMBLY NO°)

PROJET

(PROJECT)

ÉCHELLE

(SCALE)

TITRE:

(TITLE)

TOLÉRANCES:

(TOLERANCES)

N° DESSIN:

(DRAWING N°)

RÉVISIONS:

(REVISION)

FRAC. /32"
x.x  ±0.01"

X.XX ±0.005"
X.XXX ±0.001"

Bouilloir 25 gallons

BK25002

 

S-0001

14-08-19

1

1:15

0

19

2

3

13

12

No.

Qté

No de pièce

Description

Matériel

1

1

BK25008

Soudure du bidon

2

1

BK25005

Assemblage du brûleur

3

1

BK25012

Soudure du chaudron

4

1

BK00130

Cache proble hi limit

S.S. 304 2B

5

1

BK00109

Couvercle du boité de contrôle

S.S. 304-4

6

1

EL01-0003

Bloc contact N.O pour bouton

7

1

FO79-0010

Bande autocollante 1/2" x 1/8" épais

NEOPRÈNE

8

1

EL01-0005

Bloc contacteur N.C pour bouton

9

1

EL37-0049

Lumière 24v ac pour bouton vert

10

1

EL01-0001

Support en plastique pour bouton

11

1

EL01-0048

Sélecteur 3 positions lumineux

12

1

BK25129

Garde valve

S.S. 304-4

13

1

BK25014

Soudure du pare éclaboussure

14

1

BK00006

Assemblage du boitié électrique

4

2

14

22

21

No.

Qté

No de pièce

Description

Matériel

15

1

EL35-0006

Fil d'allumage 36"

16

1

BK25015

Assemblage soudé couvercle

17

1

BK25115

Pare feu

S.S. 304 2B

18

1

BK25016

Grille du drain du chaudron

19

4

ME41-0067

Patte ajustable 3/4-10 - 6" - acier

inoxydable

S.S.

20

4

QU28-0022

Vis machine ronde étoile 10-24  x 1/2

acier inoxydable

S.S.

21

4

QU28-0093

Vis tête goutte de suif 1/4-20 x 1/2 18.8 ss

22

4

QU28-0054

Rondelles plates 1/4 ss

S.S.

23

4

QU28-0030

Boulon 1/4 x 3/4 NC autotaraudeuse type f

hexagone avec épaulement

1:7

5

20

7

11

10

6

9

8

12

17

23

3

15

16

Summary of Contents for BK-25N

Page 1: ...MU BK GA 00 16 Septembre 2014 INSTRUCTION MANUAL PICARD KETTLE MODEL BK 25N BK 25P BK 45N BK 45P SERIAL NUMBER...

Page 2: ...2...

Page 3: ...TCHES DO NOT USE A TELEPHONE IN YOUR LOCAL 4 IMMEDIATELY CONTACT YOUR GAS SUPPIER USING A NEIGHBOR S PHONE 5 IF YOU CANNOT REACH YOUR GAS SUPPLIER CONTACT THE FIRE DEPARTMENT WARNING Improper installa...

Page 4: ...4...

Page 5: ...MEDIATELY CONTACT A QUALIFIED SERVICE TECHNICIAN TO INSPECT THE APPLIANCE AND REPLACE ANY PARTS OF THE CONTROL SYSTEM AND GAS CONTROL SYSTEM WHICH WERE SUBMERGED UNDER WATER NOTE THIS MANUAL SHOULD BE...

Page 6: ...6...

Page 7: ...ive is involved and is responsible for The installation of gas lines from the outlet side of the gas meter or service regulator when a meter is not present and the connection and installation of the g...

Page 8: ...8...

Page 9: ...9 LABELS YOU WILL FIND ON YOUR OVEN ATTENTION BR LANT C A U T I O N H O T...

Page 10: ...10...

Page 11: ...11...

Page 12: ...12...

Page 13: ...ONS ___________________________________________________________ Pg 22 KETTLE START UP _______________________________________________________________ Pg 22 KETTLE SHUT DOWN ___________________________...

Page 14: ...14...

Page 15: ...nicians committed to excellence completed the construction of this certified equipment MANUFACTURING OVENS USING STATE OF THE ART TECHNOLGIE Rugged efficient and easy to use the Picard Kettle is well...

Page 16: ...16 This page has been left blank intentionally...

Page 17: ...17 SECTION INSTALLATION EXTERNAL DIMENSIONS BK 45...

Page 18: ...18 EXTERNAL DIMENSIONS BK 25...

Page 19: ...ERAL COMPONENTS 1 Gas hook up inch NPT 2 Control button 3 Splash guard 4 Cauldron 5 Electrical panel 6 Exhaust 8 OD 203 mm 7 Drain 2 NPT BK 45 1 NPT BK 25 8 Cover 9 Drain strainer 10 Flame verificatio...

Page 20: ...14 WATER COLUMN LOW W C HI W C BK 45N 65 Natural 112 000 4 6 WATER COLUMN LOW 1 0 W C HI 3 5 W C BK 45P Propane 12 14 WATER COLUMN LOW W C HI W C ATTENTION The temperature high limit alarm must alway...

Page 21: ...maintenance WARNING All venting plumbing and electrical hook ups must be in accordance with federal state or local code and are the responsibility and cost of the client This kettle must be installed...

Page 22: ...l ventilation connections must in installed to conform to national provincial or municipal codes in effect The type of ventilation hood must be chosen by a professional as this may vary depending on t...

Page 23: ...Ensure that the burner has been ignited SHUT DOWN INSTRUCTION 1 Turn the selector button to the OFF position WHAT TO DO IF YOU SMELL GAS 1 Close immediately the manual gas valve 2 Do not try to turn o...

Page 24: ...24 CONTROL PANEL OPERATION OFF Turns off the burner LOW Reduce the burner to low fire rate Use this mode once the water is boiling HI Increase the burner to maximum fire rate...

Page 25: ...Y A Clean the kettle in general Client B Clean the burner pilot Distributor Certified technician C Change the burner pilot and wire Distributor Certified technician D Verify and clean the burner Distr...

Page 26: ...uids from dripping as they can infiltrate into the electrical and mechanical components causing short and long term problems Avoid the use of scouring pads on stainless steel Avoid water to enter the...

Page 27: ...27 SPARE PARTS No Quantity Description Part No Maintenance Reference 1 1 Pilot PL69 0017 2 1 Ignition wire EL35 0006 3 1 Fuse 5 amps EL36 0006...

Page 28: ...n your gas line is in the open position Verify that the gas pressure is between 4 and 6 inches of water column for natural gas and 10 to 12 inches of water column for propane The Igniter isn t functio...

Page 29: ...e gas line pressure Verify the gas manifold pressure 1 0 W C on LOW 3 5 W C on HI Natural gas W C on LOW W C on HI Propane gas Yes No Note the gas manifold pressure Verify that the burner works Yes No...

Page 30: ...30 ELECTRIC PLANS...

Page 31: ...31...

Page 32: ...the client The form may be faxed or mailed to Picard Ovens at the coordinates found at the bottom of the page Proper maintenance procedures are found in the operators guide Precisions and limitations...

Page 33: ...quipment or any part is damaged as a result of accident casualty alteration misuse abuse improper cleaning improper installation improper operation including improper tray loading resulting in shelf j...

Page 34: ...34 A P P E N D I X...

Page 35: ...0010 Bande autocollante 1 2 x 1 8 pais NEOPR NE 8 1 EL01 0005 Bloc contacteur N C pour bouton 9 1 EL37 0049 Lumi re 24v ac pour bouton vert 10 1 EL01 0001 Support en plastique pour bouton 11 1 EL01 00...

Page 36: ...ntit No de pi ce DESCRIPTION Mat riel 1 1 BK45011 Assemblage soud du br leur 2 1 PL69 0017 tincelle d allumage intermittent 3 1 PL07 0024 Valve gaz 2 stages 24V 4 1 PL07 0011 Valve bille 3 4 IPS NCI g...

Page 37: ...79 0010 Bande autocollante 1 2 x 1 8 pais NEOPR NE 8 1 EL01 0005 Bloc contacteur N C pour bouton 9 1 EL37 0049 Lumi re 24v ac pour bouton vert 10 1 EL01 0001 Support en plastique pour bouton 11 1 EL01...

Page 38: ...ntit No de pi ce DESCRIPTION Mat riel 1 1 BK25011 Assemblage soud du br leur 2 1 PL69 0017 tincelle d allumage intermittent 3 1 PL07 0024 Valve gaz 2 stages 24V 4 1 PL07 0011 Valve bille 3 4 IPS NCI g...

Page 39: ...8 1 1 3 0 NOTES FIXER AVEC VIS TEK 2 9 10 8 5 4 3 1 6 No Quantit No de pi ce DESCRIPTION Mat riel 1 1 BK00113 Plaque de fond du boiti lectrique S S 304 2B 2 1 EL02 0008 Contr le d allumage lectronique...

Page 40: ...1 EL02 0104 Contr le de temp rature maximale120V Fahrenheit 4 1 BK00013 Soudure porte du boit lectrique 5 1 QU59 0058 Serrure quart de tour 6 1 FO79 0019 Bande autocollante en D EPDM 3 8 x 1 4 7 1 EL8...