29
Verification list
Client:
Dealer
Installation date:
Model:
Serial Number:
Circle one
Gas connections already installed on site
Yes
No
Ventilation Hood Installed
Yes
No
Verify all buttons of control panel
Yes
No
Do you have a pressure Indicator (U tube)
Yes
No
Verify gas pressure is between 4 - 6 W.C for natural gas and 10 –
12 W.C. for propane
Yes
No
Note the gas line pressure:
Verify the gas manifold pressure: 1.0” W.C. on ”LOW” - 3.5” W.C.
on “HI” (Natural gas) / ” W.C. on “LOW” – ” W.C. on “HI” (Propane
gas)
Yes
No
Note the gas manifold pressure
Verify that the burner works
Yes
No
Verify that there isn't negative pressure while all venting systems
in the building are in operation.
Yes
No
Person in charge of the kettle
Understands how to use the kettle the right way and safely
Yes
No
Understands maintenance
Yes
No
Understand who to contact for service.
Yes
No
Notes:
Customer's name (print): Signature:
Installer's name ( print): Signature: