- Remove the oil pump and collect the gasket.
Inspection
- Remove the two screws and remove the oil pump
cover.
- Remove and wash the rotors thoroughly with pet-
rol and compressed air.
- Reassemble the rotors in the pump body, keep-
ing the two reference marks visible.
- Using a feeler gauge, check the distance be-
tween the rotors in the position shown in the figure.
- Check the distance between the outer rotor and
pump body, see figure.
Check the axial clearance of the rotors using a
trued bar as shown in the figure.
Characteristic
Axial rotor clearance
Limit value admitted: 0.09 mm
Distance between the outer rotor and the pump
body
Admissible limit clearance: 0.20 mm
Distance between the rotors
Admissible limit clearance: 0.12 mm
Engine
Beverly 400 E5
ENG - 146
Summary of Contents for Beverly 400 E5
Page 1: ...MANUALE STAZIONE DI SERVIZIO 1Q000884 Beverly 400 E5...
Page 4: ......
Page 6: ...INDEX OF TOPICS GENERAL MANDATORY REQUIREMENTS NORM...
Page 9: ...INDEX OF TOPICS PRE DELIVERY PRE DE...
Page 17: ...INDEX OF TOPICS TECHNICAL DATA DT...
Page 23: ...Beverly 400 E5 Technical Data DT 23...
Page 24: ...Technical Data Beverly 400 E5 DT 24...
Page 26: ...Technical Data Beverly 400 E5 DT 26...
Page 28: ...Technical Data Beverly 400 E5 DT 28...
Page 30: ...Technical Data Beverly 400 E5 DT 30...
Page 43: ...INDEX OF TOPICS TOOLING TOOL...
Page 52: ...Stores code Description 021017Y EOBD E5 diagnostics cable Tooling Beverly 400 E5 TOOL 52...
Page 53: ...INDEX OF TOPICS MAINTENANCE MAIN...
Page 67: ...INDEX OF TOPICS ELECTRICAL SYSTEM ELE SYS...
Page 82: ...INDEX OF TOPICS ENGINE ENG...
Page 92: ...Engine Beverly 400 E5 ENG 92...