Z Mounting Overview
The mounting bracket for the L-505 can be attached in two different configurations.
Requirements
✓
You have read and understood the
general safety instructions (p. 8)
.
✓
The positioners are not connected to the electronics.
✓
The lower positioner has been
mounted onto the underlying surface properly (p. 13)
.
✓
You have accounted for the space required to route cables without bending and
according to regulations.
NOTICE
Impermissibly high load on the positioners!
In a multi-axis system, the stage used for the upper axis must also be moved. Impermissibly
high loads impair the motion and can damage the positioners.
►
Pay attention to the
maximum permissible forces (p. 32)
that may act on the motion
platform.
►
In the case of multi-axis systems, include the masses of the positioners to be moved
when calculating the load.
NOTICE
Unwanted changes in position with vertical mounting!
If the load exceeds the self-locking of the L-505.01A200F when the stage is mounted
vertically, unwanted changes in the position of the motion platform will occur. Unwanted
changes in the position of the motion platform can damage the drive, the load or the
environment.
►
If the L-505.01A200F is mounted vertically, make sure that the installed load is lower than
the self-locking of the drive. (see
Specifications (p. 32)
)
NOTICE
Excessively long screws and locating pins
Screws and locating pins that are inserted too deeply can damage the L-505.01A200F.
►
Pay attention to the
depth of the mounting and locating holes (p. 36)
in the
L-505.01A200F.
►
Only use screws and locating pins of the correct length for the respective mounting holes.
6 INSTALLATION
L505M0011EN
‒
10/22/2018
18