Table 1: Overview of the functional elements of the control panel 
 

No. Name/Type 

Function 

Lighting colour:
function activated 

Triangular warning symbol 
“X-rays” 

X-ray status indication 

Bright yellow ( 2 LEDs) 

II 

Lighting (button) 

For switching the light in the experiment chamber on/off 

Green 

III 

Loudspeaker (button) 

Acoustic indication of the pulses 

Green 

IV 

Door status (button) 

For locking and unlocking the door 

White:  
 not 

lockable 

Left LED green: 
 

door can be locked 

right LED green: 
 door 

locked 

X-rays (button) 

For activating the X-radiation 

White: it is not possible  
 

to swith on the unit 

Left LED green: 
 

X-ray can be activated 

right LED green: 
 

X-ray is activated 

VI 

Button (no name) 

The selection of the menu function will be displayed on the 
screen above (on the bottom on the left-hand side) 

White 

VII 

Button (no name) 

The selection of the menu function will be displayed on the 
screen above (on the bottom on the right-hand side) 

White 

VIII  Arrow key “up” (button) 

For setting experiment parameters and for scrolling through 
the menu 

White 

IX 

Arrow key “down” (button) 

For setting experiment parameters and for scrolling through 
the menu 

White 

Enter (button) 

For confirming the selected value 

White 

XI TFT 

display 

For displaying the menus for the manual control of the unit 
(77

mm x 50

mm) 

Polychrome 

 
 

 

 
 

 

 
 
 
 
 

Fig. 5: Control panel at the front of the unit 

VIII

IX 

XI 

II 

III 

IV  

VI 

VII

Summary of Contents for XR 4.0

Page 1: ...se in dry and dust free rooms where there is no risk of explosion Prior to connecting the unit to the mains power supply ensure that the protective conductor of the power supply unit is correctly conn...

Page 2: ...g mobile phones should not be used in the direct vicinity of the unit The connected cables must not be longer than 2 m Electrostatic charges or similar electromagnetic phe nomena HF bursts indirect li...

Page 3: ...ography of objects and observation with the aid of a fluoroscopic screen Preparation of X ray images of irradiated objects Detection of the ionising effect of X rays dosimetry Detection of Bragg refle...

Page 4: ...ww phywe com All rights reserved 09057 99 2115 Fig 2 Front view of the XR 4 0 X ray expert unit 09057 99 including X ray tube Fig 3 View from the right side XR 4 0 X ray expert unit 09057 99 1 4 2 3 5...

Page 5: ...side of the unit looping through This enables for ex ample the control or read out from the outside of a digital camera that is located inside the experiment chamber 5 2 4 Working channel D The worki...

Page 6: ...sible to swith on the unit Left LED green X ray can be activated right LED green X ray is activated VI Button no name The selection of the menu function will be displayed on the screen above on the bo...

Page 7: ...4 0 X ray expert unit Make sure that the plug in is inserted completely Otherwise it is not going to work Handle the plug ins with care 5 6 Socket panel inside the experiment chamber 5 Fig 7 Socket pa...

Page 8: ...g door is not locked with the lock bar If so unlock the door using but ton IV Fig 5 switch on the device to use the button The door should not be open either fix it with the S LOCK 6 2 Start up Connec...

Page 9: ...and 35 0 kV and the emission current to a value between 0 00 mA and 1 00 mA 6 4 2 Goniometer Menu and parameterisation of the goniometer 09057 10 The operation of the goniometer in the X ray unit is...

Page 10: ...all functionalities according to table 2 of this oper ating instruction In operating state 1 and 2 it is not possible to acti vate the x radiation In operating state 3 the x radiation is not active t...

Page 11: ...R 4 0 X ray Chemical set for edge absorption 09058 11 XR 4 0 X ray Crystal holder for Laue pattern 09058 09 XR 4 0 X ray holder for powder probes diffrac tometry 09057 08 XR 4 0 X ray film holder 0905...

Page 12: ...PHYWE Systeme GmbH Co KG Customer Service Robert Bosch Breite 10 37079 G ttingen Germany Telephone 49 0 551 604 274 Fax 49 0 551 604 246 13 APPENDIX Symbols Warning Warning radioactive sub stance or...

Page 13: ...e mount for optical bench h 30 mm x 10 09058 04 XR 4 0 X ray Compton attachment for x ray unit 11 08286 01 Slide mount for optical bench h 30 mm x 12 09057 01 XR 4 0 X ray Diaphragm tube d 1 mm 09057...

Reviews: