Operating Instructions 

XR 4.0 expert unit, X-ray unit, 35

kV 

 

09057-99 

PHYWE Systeme GmbH & Co. KG 
Robert-Bosch-Breite 10 
37079 Göttingen 
Germany 
 
Tel  

+49

(0)

551

604-0 

Fax  

+49

(0)

551

604-107 

E-mail [email protected] 

 

 

Fig. 1: 09057-99, XR 4.0 expert unit, X-ray unit, 35

kV

 

 

The unit complies 
with the applicable 
EC regulations. 

 

 

1

 

SAFETY INSTRUCTIONS

 

2

 

OPERATING INSTRUCTIONS

 

3

 

INSTRUCTIONS OF THE GERMAN X-RAY 

ORDINANCE

 

4

 

PURPOSE AND CHARACTERISTICS

 

5

 

FUNCTIONAL AND OPERATING ELEMENTS

 

6

 

OPERATION

 

7

 

CHECKLIST

 

8

 

TECHNICAL DATA

 

9

 

SCOPE OF SUPPLY

 

10

 

ACCESSORIES

 

11

 

WARRANTY

 

12

 

DISPOSAL

 

13

 

APPENDIX

 

1 SAFETY 

INSTRUCTIONS 

 

  Read the operating instructions thoroughly and com-

pletely prior to starting the unit. This is important for your 
own protection and for avoiding damage to the unit. 

 

Use the unit solely for its intended purpose. 

  The unit is intended for use in dry and dust-free rooms 

where there is no risk of explosion. 

  Prior to connecting the unit to the mains power supply, 

ensure that the protective conductor of the power supply 
unit is correctly connected to the protective conductor of 
the mains power supply network. The mains power plug 
may only be plugged into a mains power socket that is 
equipped with a protective conductor. Do not eliminate 
this protective effect by using an extension lead without a 
protective conductor. 

  Ensure that the mains voltage that is stated on the type 

plate of the unit matches the mains voltage of your power 
supply network. 

  When setting the unit up, ensure that the mains power 

switch and the device plug are freely accessible. Ensure 
also that the venting slots of the unit are not covered or 
blocked. 

  Do not connect any devices to the unit other than the 

ones that are intended for this purpose. 

  Attention: Disconnect the unit from the power supply 

prior to loosening, replacing, or removing any of the ca-
ble connections! 

  Ensure that no liquids or objects penetrate the unit 

through the venting slots. 

Summary of Contents for XR 4.0

Page 1: ...se in dry and dust free rooms where there is no risk of explosion Prior to connecting the unit to the mains power supply ensure that the protective conductor of the power supply unit is correctly conn...

Page 2: ...g mobile phones should not be used in the direct vicinity of the unit The connected cables must not be longer than 2 m Electrostatic charges or similar electromagnetic phe nomena HF bursts indirect li...

Page 3: ...ography of objects and observation with the aid of a fluoroscopic screen Preparation of X ray images of irradiated objects Detection of the ionising effect of X rays dosimetry Detection of Bragg refle...

Page 4: ...ww phywe com All rights reserved 09057 99 2115 Fig 2 Front view of the XR 4 0 X ray expert unit 09057 99 including X ray tube Fig 3 View from the right side XR 4 0 X ray expert unit 09057 99 1 4 2 3 5...

Page 5: ...side of the unit looping through This enables for ex ample the control or read out from the outside of a digital camera that is located inside the experiment chamber 5 2 4 Working channel D The worki...

Page 6: ...sible to swith on the unit Left LED green X ray can be activated right LED green X ray is activated VI Button no name The selection of the menu function will be displayed on the screen above on the bo...

Page 7: ...4 0 X ray expert unit Make sure that the plug in is inserted completely Otherwise it is not going to work Handle the plug ins with care 5 6 Socket panel inside the experiment chamber 5 Fig 7 Socket pa...

Page 8: ...g door is not locked with the lock bar If so unlock the door using but ton IV Fig 5 switch on the device to use the button The door should not be open either fix it with the S LOCK 6 2 Start up Connec...

Page 9: ...and 35 0 kV and the emission current to a value between 0 00 mA and 1 00 mA 6 4 2 Goniometer Menu and parameterisation of the goniometer 09057 10 The operation of the goniometer in the X ray unit is...

Page 10: ...all functionalities according to table 2 of this oper ating instruction In operating state 1 and 2 it is not possible to acti vate the x radiation In operating state 3 the x radiation is not active t...

Page 11: ...R 4 0 X ray Chemical set for edge absorption 09058 11 XR 4 0 X ray Crystal holder for Laue pattern 09058 09 XR 4 0 X ray holder for powder probes diffrac tometry 09057 08 XR 4 0 X ray film holder 0905...

Page 12: ...PHYWE Systeme GmbH Co KG Customer Service Robert Bosch Breite 10 37079 G ttingen Germany Telephone 49 0 551 604 274 Fax 49 0 551 604 246 13 APPENDIX Symbols Warning Warning radioactive sub stance or...

Page 13: ...e mount for optical bench h 30 mm x 10 09058 04 XR 4 0 X ray Compton attachment for x ray unit 11 08286 01 Slide mount for optical bench h 30 mm x 12 09057 01 XR 4 0 X ray Diaphragm tube d 1 mm 09057...

Reviews: