phytron
23
MA 1273-A007 EN
6.1.1 Assembly Rules
Observe the following when installing a POWM01/POWM02 module:
POWM01 and POWM03
Each configuration starts with a POWM01 or POWM03 main supply and configuration
module. Then mount a CPU module MCM01 or MCM02 which also contain a selectable
host interface module.
POWM01 and POWM02
Each supply module:
- Can supply at maximum of 10 further modules with the internal logic voltage (
5 V
).
- May exceed 20 A at
24–70 V
DC
at any time from the power supply unit – this may
limit the number of axis cards which can be supplied.
- Can supply a total of 5 A from the
24 V
DC
I/O supply for the outputs (analogue,
digital) or for the supply to limit switches.
POWM03 and POWM04
Each supply module:
- Can supply at maximum of 10 further modules with the internal logic voltage (
5 V
).
- May exceed 20 A at
48/70 V
DC
at any time from the power supply unit – this may
limit the number of axis cards which can be supplied.
- Can supply a total of 5 A from the
24 V
DC
I/O supply for the outputs (analogue,
digital) or for the supply to limit switches...
- Can supply a total of 5 A from the
24 V
DC
output for loads.
If any of these conditions is exceeded, an additional intermediate module POWM02 or
POWM04 must be provided, or an autonomous
phy
MOTION
™ ( MCM01 or
MCM01…) should be considered.
The total current at + 24V
DC
for all inputs / outputs, as well as limit and reference switches,
encoders and sensors incl. the 24 V
DC
tap of POWM03 / 04 modules must not exceed the
value of 5 A per total
phy
MOTION
TM
.
Power modules can only be plugged into the designated slots. You must define these slots
before ordering.
An intermediate module can also be used to separate the motor supply voltage on the rear
backplane. Thus two different motor power supplies can be driven in the
phy
MOTION
™.
Be careful that no slots are left empty ensure correct addressing of the modules.