Before integrating or switching modules always make sure that the
phy
MOTION
™ is shut
down and the power supplies are disconnected.
WARNING – Serious injury from electric shock!
During electrical installation cables, connectors, etc. can be live.
- Before starting wiring, make sure that none of the power supplies are
connected to the primary side of the mains supply. Isolate the power
supplies from the mains or remove the appropriate fuses.
- All modules must be inserted and screwed into the
phy
MOTION
TM
housing before powering up. If necessary, unoccupied module slots
must be covered with the supplied blank front plates.
Never operate the equipment when open.
- Do not plug or unplug the modules while powered.
- Do not plug or unplug the connectors while powered.
- If the equipment was energised, wait 3 minutes after power off to
allow the capacitors to discharge and ensure that there are no
residual charges on cables, connectors and boards.
Make sure not to leave free slots in between modules so the module addressing sequence
can work correctly.
Identify the correct slot position for your I4XM01 referring to your order and
documentation. The I4XM01 module needs up to 4 INAM01 or EXAM01 modules,
one POWM01 or POWM02 and the main controller module (MCM01).
The I4XM01 module is always built as a sandwich with its subsequent INAM01 and / or
module cards EXAM01.
Connect the I4XM01 module with the connector (2x13 poles, ribbon cable) to the
appropriate INAM01 and/or EXAM01 modules from the rear side.
Push the sandwich module carefully into the guide rail until the rear contacts the housing
frame of the
phy
MOTION
TM
In the last few millimetres the module’s plug has to match with the backplane’s socket. You
should be able to push in the module with light pressure. In case you experience problems
move the module’s front plate slightly to the left and to the right while pushing in the
module, so that the plug’s pins can slide into the backplane’s socket.
As soon as the module’s front plate contacts the housing’s frame the module is integrated
properly and can be fixed with two electro-conductive bolts.
Now you can start with the electrical installation.