Trouble-Shooting
PHYTEC Meßtechnik GmbH 2004 L-608e_4
187
m
The integrated supply voltage does not function and the green
LEDs fail to illuminate.
l
Check the model number, is it an EPC-032-X2 or an
EPC032-X1-X2? The adapter is only present with these
models.
l
Is the input voltage connected (8 to 25 V / 15 to 25 VDC)?
l
Is the polarity of the input voltage correct?
l
Is the plug correctly connected to X300?
l
Is the circuit breaker SI301 functioning?
l
Has a short circuit / overload occurred (adapter shuts off)?
l
Was the adapter switched off over connector X301? For
operation X301 must be open or Pin 1 has to be on HIGH
level. If necessary, as a test, remove one of the connectors
from X301.
m
The green LED for +12 V does not illuminate and the 12 V
output voltage is not present. The +5 V supply voltage functions.
l
The input voltage is below +15 VDC. At least a 15 V input
voltage is required for operation of the 12 V branch of the
adapter.
l
A short circuit has occurred in the 12 V branch or the current
draw is too high.
Summary of Contents for eGrabber-4plus
Page 8: ...eGrabber 4plus PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Page 10: ...eGrabber 4plus PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Page 56: ...eGrabber 4plus 46 PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Page 80: ...eGrabber 4plus 70 PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Page 81: ...Part 2 Programmer s Manual PHYTEC Meßtechnik GmbH 2004 L 608e_4 71 Part 2 Programmer s Manual ...
Page 82: ...eGrabber 4plus 72 PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Page 188: ...eGrabber 4plus 178 PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Page 192: ...eGrabber 4plus 182 PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Page 204: ...eGrabber 4plus 194 PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Page 206: ...Published by PHYTEC Meßtechnik GmbH 2004 Ordering No L 608e_4 Printed in Germany ...