Supply Voltage:
(only models EPC-032-X / EPC-032-X1-X2)
Input Voltage:
8 … 28 VDC
Output Voltages:
+5 VDC / 2 A
+12 VDV / 1A
When using the +12 V output, the input
voltage must lie within the range of
15…28 V
Output Level:
22 W max.
Shut down:
electronic, TTL-Signal
Connectors:
2 SMB-Sockets:
X1 = Composite Channel 1
X2 = Composite Channel 2
26-pin male connector
Composite channel 1-3
(EPC-032-X1: channels 1-9)
S-Video chroma signal
(luma on Composite 9)
1 I²C interface
1 supply voltage output 1.5 A max
1 I/0 connector, transistor operated
Mini-DIN socket X4:
1 S-Video input
Male Connector 2x10 X6:
GPIO-Port, 12 x TTL I/O
1 I²C interface
1 I/O connector, transistor operated