The eGrabber-4plus has an internal non-volatile memory. This
memory is intended for the storage of parameters.
A total of 252Bytes is available to the user.
Note:
Since the predecessor models to the eGrabber-4plus do not include
internal memory, the following functions are not compatible.
BYTE I2C_ReadEEProm (WORD nDevNo, BYTE bSubAddress,
BYTE *bByteRead)
bSubAddress:
Memory address to be read (0x00 … 0xFB
*bByteRead:
Pointer points to the Byte variable. The result
is written into the Byte variable.
return value: error code = SUCCESS, NOACK
Reads a Byte value from the EEPROM. Specified by calling the
memory address that is to be read. The result is returned in a Byte
variable form that must be pre-defined.
The function returns an error code as a return value
(see I²C_ReadByte).
BYTE I2C_WriteEEProm (WORD nDevNo, BYTE bSubAddres,
BYTE bData)
bSubAddress:
memory address written to (0x00…0xFB
bData:
Data byte that is written
return value: Error code = SUCCESS, NOACK, WRITE_FAILED
Writes a Byte into the internal EEPROM. Specifies the desired
memory address and the stored Byte to be written to.
The function returns an error code (see I2C_WriteByte).
Note:
The life span of the internal EEPROM memory is 1 million write
accesses. The number of read accesses is unlimited.
Summary of Contents for eGrabber-4plus
Page 8: ...eGrabber 4plus PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Page 10: ...eGrabber 4plus PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Page 56: ...eGrabber 4plus 46 PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Page 80: ...eGrabber 4plus 70 PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Page 81: ...Part 2 Programmer s Manual PHYTEC Meßtechnik GmbH 2004 L 608e_4 71 Part 2 Programmer s Manual ...
Page 82: ...eGrabber 4plus 72 PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Page 188: ...eGrabber 4plus 178 PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Page 192: ...eGrabber 4plus 182 PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Page 204: ...eGrabber 4plus 194 PHYTEC Meßtechnik GmbH 2004 L 608e_4 ...
Page 206: ...Published by PHYTEC Meßtechnik GmbH 2004 Ordering No L 608e_4 Printed in Germany ...