1.3
Minimum Requirements to Operate the Display
Adapters
1.3.1
PDI Power Supply Connector
Operation of the display adapters only requires supply of two input
voltages (+3.3V with a 1A load and +5V with a 2A load) and the
corresponding GND connections.
These supply pins are located at the PDI power connector X3:
LCD_3V3: X3
2
LCD_5V:
X3 4, 6, 8
Connect all power input pins to your power supply and all GND pins.
Corresponding GND:
X3 1, 3, 5, 7, 9
There are also pins reserved for 12V backlight supply but currently
not used.
Caution:
On a custom board we recommend connecting all ava5V input
pins and at least the matching number of GND pins to the power
supply system.
Please refer to
section 3
for more information.
1.3.2
PDI Data Connector
In order to drive a display at least the LVDS signals, 3V3 logic supply
voltage, the /display_enable signal and GND are needed. If the display
has touch, then you also need to connect the pins for the touch.
Summary of Contents for 1337.1
Page 10: ...Display Adapter LCD 014 x LCD 017 x viii PHYTEC Messtechnik GmbH 2011 L 758e_1...
Page 24: ...Display Adapter LCD 014 x LCD 017 x 14 PHYTEC Messtechnik GmbH 2011 L 758e_1...
Page 30: ...Display Adapter LCD 014 x LCD 017 x 20 PHYTEC Messtechnik GmbH 2011 L 758e_1...
Page 36: ...Display Adapter LCD 014 x LCD 017 x 26 PHYTEC Messtechnik GmbH 2011 L 758e_1...
Page 40: ...Display Adapter LCD 014 x LCD 017 x 30 PHYTEC Messtechnik GmbH 2011 L 758e_1...
Page 42: ...Display Adapter LCD 014 x LCD 017 x 32 PHYTEC Messtechnik GmbH 2011 L 758e_1...
Page 44: ...Published by PHYTEC Me technik GmbH 2011 Ordering No L 758e_1 Printed in Germany...