Connectors
©
PHYTEC Messtechnik GmbH 2011 L-758e_1
11
2.2
Display Connectivity (X2)
The display connector X2 is specific to the Primeview Displays used
by PHYTEC for these display adapters. In many cases other displays
need another pin assignment or even a completely different connector.
Pin # Signal name
SL
Description
1
LCD_3V3_S
3.3V
+3V3 Logic Supply Voltage
2
LCD_3V3_S
3.3V
+3V3 Logic Supply Voltage
3 GND
Ground
4 GND
Ground
5
DISP_LVDS_0-
LVDS
LVDS data channel 0 negative input
6
DISP
LVDS
LVDS data channel 0 positive input
7 GND
Ground
8
DISP_LVDS_1-
LVDS
LVDS data channel 1 negative input
9
DISP
LVDS
LVDS data channel 1 positive input
10 GND
Ground
11
DISP_LVDS_2-
LVDS
LVDS data channel 2 negative input
12
DISP
LVDS
LVDS data channel 2 positive input
13 GND
Ground
14
DISP_LVDS_CLK-
LVDS
LVDS clock channel negative input
15
DISP_L
LVDS
LVDS clock channel positive input
16 GND
Ground
17
DISP_LVDS_3-
LVDS
LVDS data channel 3 negative input
18
DISP
LVDS
LVDS data channel 3 positive input
19 GND
Ground
20 GND
Ground
21
GND
1
Ground
22 GND¹
Ground
Table 4:
Display connector signal description
1
LCD-014 connects this to shield, but the connected display closes shield with GND
Summary of Contents for 1337.1
Page 10: ...Display Adapter LCD 014 x LCD 017 x viii PHYTEC Messtechnik GmbH 2011 L 758e_1...
Page 24: ...Display Adapter LCD 014 x LCD 017 x 14 PHYTEC Messtechnik GmbH 2011 L 758e_1...
Page 30: ...Display Adapter LCD 014 x LCD 017 x 20 PHYTEC Messtechnik GmbH 2011 L 758e_1...
Page 36: ...Display Adapter LCD 014 x LCD 017 x 26 PHYTEC Messtechnik GmbH 2011 L 758e_1...
Page 40: ...Display Adapter LCD 014 x LCD 017 x 30 PHYTEC Messtechnik GmbH 2011 L 758e_1...
Page 42: ...Display Adapter LCD 014 x LCD 017 x 32 PHYTEC Messtechnik GmbH 2011 L 758e_1...
Page 44: ...Published by PHYTEC Me technik GmbH 2011 Ordering No L 758e_1 Printed in Germany...