background image

 System Description

 

 

11 / 34 

Ethernet/IP Functionality 

 

General Bridging Function 

 

Support IPv4 packet 

 

Support IEEE802.1d Ethernet bridge function between 
trunk Ether port and ATM VCs 

 

Support Rapid Spanning Tree Protocol (RSTP) for the 
trunk interfaces per IEEE 802.1w 

 

Support static source MAC table provisioning, 
automatic source MAC learning and block duplicate 
ones 

 

The system is able to maintain 4K entries in its own 
static MAC address table and to provision up to a 
maximum of 128 MAC entries per line port 

 

VLAN 

 

Support IEEE 802.1q Port-based VLAN and 
Protocol-based VLAN 

 

Support 512 non-stacked VLAN-ID simultaneously 
ranging from 1 to 4095 

 

Support VLAN stacking and VLAN cross-connect 

 

Support IP Spoofing prevention 

 

Support MAC anti-Spoofing 

 

Support port isolation functionality. When port 
isolation is enabled, no Layer-2 bridging between 
different ports (or subscriber lines) is supported in a 
VLAN 

 

Support static VLAN group and membership 
provisioning 

 

Multicast 

 

Support IP multicast forwarding and the multicast 
works well for RFC2684 bridged payload 
encapsulation mode 

 

Support up to 256 multicast groups and 256 copies 
simultaneously 

 

Support profile-based Multicast Access Control (up to 
48 profiles) and assign any profile to a subscriber 
interface (the number of multicast channels within a 
profile is 256) 

 

Support to limit maximum number of IGMP groups 
joined per bridge port 

 

Support IGMP snooping/proxy per IGMP v1, v2, and 
v3 

 

Support selection between IGMP proxy and IGMP 
snooping 

 

ACL/Filtering 

 

Support Layer-2 frame filtering based on 
source/destination MAC addresses and EtherType 

 

Support Layer-3 filtering based on IP header including 

Summary of Contents for UniPhyer LB-UA2324

Page 1: ...B UA2324 24 Port UniPhyer LB UA2348 48 Port UniPhyer LB PA111 PhyAdapter LB PA110 Extended Reach PhyAdapter Two wire Network Line Bridge Gateway System Description Part Number 8003 02 Issue 3 May 2009...

Page 2: ......

Page 3: ...7 1 3 1 Physical Specifications 7 1 3 2 Environmental Specifications 7 1 3 3 Power Specifications 7 1 3 4 Line Length Specifications 7 1 4 Detailed Description of the UniPhyer LB UA2348 8 1 4 1 Module...

Page 4: ...Contents 1 7 Performance management 22 1 7 1 RMON Feature 25 1 8 Fault Management 27 1 9 Loopback Testing 29 1 10 Cluster Feature 30 Abbreviations 32...

Page 5: ...nt Panel View 3 Figure 1 2 UniPhyer LB UA2348 system application 5 Figure 1 3 UniPhyer LB UA2348 Module Functional Block Diagram 8 Figure 2 1 Management Software Model 18 Figure 2 2 Cluster network to...

Page 6: ...es List of Tables Table 1 1 UniPhyer LB UA2348 Controls and Indicators 14 Table 2 1 RMON ETH Statistics variables 25 Table 2 2 RMON ETH History Control variables 26 Table 2 3 UniPhyer LB UA2348 Alarm...

Page 7: ...ngineers or operating personnel who want to have a basic understanding of the UniPhyer Related Documentation For information about installing operating and maintaining and troubleshooting the UniPhyer...

Page 8: ...Phyer LB UA2348 and LB UA2324 1 2 Technical Summary of the UniPhyer LB UA2324 and LB UA2348 1 3 Technical Summary of the PhyAdapter LB PA110 and LB PA111 1 4 Detailed Description of the UniPhyer LB UA...

Page 9: ...nced Quality of Service QoS features to further customize deployment to meet network needs The UniPhyer LB UA2348 provides two uplink trunk ports with both electrical and optical Gigabit Ethernet GbE...

Page 10: ...port Link Aggregation in IEEE 802 3ad that allows 2 GBE links to be aggregated together as a logical link Support both LACP protocol dynamic for load sharing and failover in case of loss of Ethernet l...

Page 11: ...ucture to create a parallel network with Power over Ethernet This is a plug and play solution that can be deployed quickly and easily with the default configuration The UniPhyer provides a permanent p...

Page 12: ...Standard rack 19 1 2 2 Environmental Specifications Item Value Operating Temperature 10 50 C Relative Humidity 10 to 95 non condensing at 35 C 1 2 3 Power Specifications Item Value Power Supply Inter...

Page 13: ...om the UniPhyer 54 V DC maximum Power Consumption 2 5 W maximum not including line or UniPhyer port power consumption which can add from 0 2 W to 0 7 W POE LB PA111 only RJ45 port provides IEEE 802 3a...

Page 14: ...processor terminates the ATM traffic into Ethernet packets through its SAR Segmentation and Reassembly function The network processor also provides the Layer 2 Ethernet functions it can support the m...

Page 15: ...or 48 ports are supplied power for the PhyAdapter and POE enabled device attached to PhyAdapter On the same port pair data signaling is provided by ADSL2 operation that comply with G 992 5 Annex M ex...

Page 16: ...r powers the PhyAdapter The RJ45 port does not provide power to the IP device an independent power supply is required for the IP device This adapter can be used beyond Management Interface In band man...

Page 17: ...upport MAC anti Spoofing Support port isolation functionality When port isolation is enabled no Layer 2 bridging between different ports or subscriber lines is supported in a VLAN Support static VLAN...

Page 18: ...ing function between ATM PVC and 802 1p priority queue Support IP CoS technology ICMP Support ICMP Internet Control Message Protocol function can send respond the ICMP request message to from other sy...

Page 19: ...n per PVC basis Support profile based ATM traffic management up to 252 profiles with one default and 251 user configurable profiles and the downstream upstream ATM profile assignments are independent...

Page 20: ...indicate the trunk port transmission speed orange color LED on the Ethernet port GBE1 Link Act GBE2 Link Act LED on RJ 45 To indicate the trunk port data activity status green color LED on the Ethern...

Page 21: ...er Line Bridge ports always have power enabled on all the ports if DSL service is enabled or not The port provides 54 V DC supply to power the Adapter and provide the POE compliant IEEE voltage to the...

Page 22: ...l have an impact on the maximum reach and cconnection performance as well as supported Class of IP phone at PhyAdapter Warning The UniPhyer Line Interface and wiring is only for intra office wiring no...

Page 23: ...17 34 Software Introduction 2 1 General Overview 2 2 Configuration Management 2 3 Performance Management 2 4 Fault Management 2 5 Loopback Testing 2 6 Cluster Feature...

Page 24: ...in the figure CLI shell SNMP agent and WEB server are in the top most layer management layer of the system software and offering OAM P function of the UniPhyer based on the conceptual management feat...

Page 25: ...ection of the system is the highest priority of all supported in band traffic categories via the GBE trunk ports Support out band management via 10 100 base T Ethernet via MGMT port Support Telnet int...

Page 26: ...agement 5 SNMP setup The configuration management provides detecting and reporting to the operators through SNMP Trap for all memory updates reflecting changes in the system configuration It also prov...

Page 27: ...aggregate transmit power Maximum PSD level PSD shape for ADSL2 Power back off initiation and Maximum aggregate receive power TCA Profile The parameters include ESs SESs UASs for interval and day PM a...

Page 28: ...ection between the UniPhyer and the PhyAdapter has been optimized for maximal System performance 1 7 Performance management Performance management supports performance monitoring by collecting and sto...

Page 29: ...rameter Occurrence date and time of the event The performance management also provides the traffic counter including transmitted packets error packets and discarded packets for each interface network...

Page 30: ...ted Total Cell Count ATUC_HEC ATM Header Error Count ATUC_IBE Idle Cell Bit Error Count ATUC_CVS The counter associated with the number of Coding Violations encountered by the channel ATUC_FECCS The c...

Page 31: ...reshold 24hour UAS threshold 24hour UAS threshold 1 7 1 RMON Feature The UniPhyer LB UA2348 supports performance statistics defined in RMON MIB groups 1 Ethernet statistics 2 history control 3 alarm a...

Page 32: ...ryOctets Monitoring rx bytes packets HistoryPkts Monitoring rx packets HistoryBroadcastPkts Monitoring rx broadcast packets HistoryMulticastPkts Monitoring rx multicast packets HistoryCRCAlignErrors M...

Page 33: ...bject For example if a far end LOS is raised on a circuit and then a far end LPR is raised on the circuit the LPR alarm stands and the LOS closes The alarm hierarchy used in the UniPhyer LB UA2348 sys...

Page 34: ...48 provides the following alarms for GBE interfaces GBE1 SFP Loss of Signal GBE2 SFP Loss of Signal ADSL Alarms The UniPhyer LB UA2348 provides the following ADSL alarms LOS Loss of Signal Near End Fa...

Page 35: ...basis according to the definition per section 8 12 3 of ITUT G992 3 The following test parameters are supported Channel Characteristics Function H f per subcarrier CCF ps Quiet Line Noise PSD QLN f p...

Page 36: ...d management interfaces The UniPhyer LB UA2348 currently provides cluster feature that a cluster can include up to four cluster members NEs There are one Master and the other members are all Slaves in...

Page 37: ...name to identify Master or Slave 4 Set private IP address on in band port for both Master and Slave UniPhyer The private IP is used for communication between Master and Slave The management center ac...

Page 38: ...lement management system DSL digital subscriber line EMC electromagnetic compatibility EMI electromagnetic immunity ETSI European Telecommunications Standards Institute Mbps megabit per second LED lig...

Reviews: