Chapter. 4
Connecting a PC
4.1. Connecting the Gigabit Ethernet Interface to a PC
The system can have the operation of its functions performed from a PC using the Gigabit Ethernet
interface.This section explains the required setup when connecting the system to a PC.
To connect a PC to the system, connect the system to a commercially available
1000BASE-T-compatible interface board with a LAN cable. For the LAN cable, prepare a UTP or STP
Cat 5e (enhanced category 5) or higher LAN cable. (UTP: Unshielded Twisted Pair, STP: Shielded
Twisted Pair)
The maximum cable length between the PC and the system is 100 m (compliant to the 1000BASE-T
specification).. One PC can connect to a maximum of 64 Photron Gigabit Ethernet interface
equipped cameras using a hub. When connecting multiple devices, connect through a switching hub
that can connect at 1000BASE-T. The maximum length of the cable that connects the system (or PC)
to the switching hub is also 100 m.
The system has two sets of Gigabit Ethernet interface connectors incorporated. Using these two
connectors simultaneously will make much faster download of image data possible.
•
For the setting method of IP address for camera system, refer to “4.1.2. Setting the IP Address”,
•
For the setting method of control PC, refer to “Photron FASTCAM Viewer User's Manual”.
•
Please refer to the [GigabitEthernet Interface Connection Tutorial Manual
」
for detail instruction on
PC connection setting.
•
About the high-speed download feature using two cables, please see the explanation in “4.1.5
High-speed Download Feature” given in page 71.
•
Photron recommends using an STP cable over long distances or in noisy locations.
•
The system is only 1000BASE-T compatible. When using a PC compatible with only 10BASE-T or
100BASE-TX, the PC must be connected through a 10BASE-T, 100BASE-TX, and 1000BASE-T
compatible switching hub.
•
The system's factory default IP address is below:
IP ADDRESS > GIGABIT ETHER1
192.168.0.10
GIGABIT ETHER2
192.168.1.10
NETMASK >
GIGABIT ETHER 1
255.255.255.0
GIGABIT ETHER 2
255.255.255.0
GATEWAY ADDRESS > 0.0.0.0
PORT > 2000 (Fixed, not changeable)
74
Summary of Contents for FASTCAM SA-Z
Page 1: ...F FA AS ST TC CA AM M S SA A Z Z...
Page 13: ...Chapter 1 Overview 1 1 Product Overview and Features 1 FASTCAM SA Z Hardware Manual...
Page 65: ...TRIG TTL IN GENERAL TTL IN TRIG SW IN SYNC IN Circuit Diagram 53 FASTCAM SA Z Hardware Manual...
Page 84: ...Chapter 3 Recording 72...
Page 90: ...Chapter 4 Connecting a PC 78...
Page 91: ...Chapter 5 Product Specifications 5 1 Specifications 79 FASTCAM SA X Hardware Manual...
Page 95: ...83 FASTCAM SA Z Hardware Manual...
Page 103: ...91 FASTCAM SA Z Hardware Manual...
Page 115: ...Chapter 6 Warranty 6 1 About the Warranty 103 FASTCAM SA Z Hardware Manual...
Page 117: ...Chapter 7 Contacting Photron 7 1 Contact Information 105 FASTCAM SA Z Hardware Manual...