FASTCAM SA-X2
34
1.3 Input / Output Signal T
ype
s
1.3.8
IRIG Time Code (External Time Synchronization)
The system supports IRIG-B input and can add an IRIG code to each recorded frame. The sample
timing for the IRIG code is once each frame.
The recorded IRIG code is displayed on a video monitor, an HD SDI monitor or "PFV".
• IRIG Code Input Specification
Connector
BNC
Code Format
IRIG-B (122) Analog
Amplitude
1.0Vp-p min, 8.0Vp-p max
Modulation Ratio
3:1 to 6:1
Typical modulated carrier signal ratio
10:1
Limitation of use of IRIG code
With the Image Trigger function, IRIG code cannot be used when the specified number of frames is 32
or fewer in RANDOM CENTER or RANDOM MANUAL trigger mode.
• IRIG Time Code is used when synchronizing a camera with external equipment in time.
It is a convenient function when apparatus is physically separated.
• When the IRIG code is being input, the IRIG code is displayed in white, and □ is displayed to the
left.
The IRIG offset time is also displayed below it. When the IRIG code is not being input, the IRIG code
is displayed in grey. At that time, the counter is the cameraʼs internal counter and it continues to
count.