FASTCAM-512PCI Hardware Manual
- 43 -
2.3.2. Sync Timing in Multi-Camera Operations
In multiple-camera operation of FASTCAM-512PCI cameras, if sync and trigger signals are
connected in series as shown below, signal delay inevitably becomes obvious. In extreme cases,
this delay may cause an offset of one full image frame between cameras involved in
multiple-camera operation. To avoid this drawback, other connection methods shown in 2.4.2. are
recommended.
Delay time in camera.
2.3.3. Delay of Vertical Sync and Trigger Signals in
Multiple-Camera Operation
In multiple-camera operation, a signal delay is caused in V sync and trigger signals between
boards.
Master Board
Internal Vsync
Approx±23nsec
Master Board
Slave Board
TRI OUT
SYNC OUT
T
-
TTL IN
SYNC IN
TRI OUT
SYNC OUT
Slave Board
SYNC IN
Slave Board
SYNC OUT
5
~
8nsec
Slave Board
Internal Vsync