01/2020
Laser class 2 devices
Model
XS, S
M, L, XL
Light source
N/A
Visible red light (laser)
Wavelength
N/A
637 nm
Peak power
N/A
18.6 mW
Average power
N/A
340 μW
Pulse energy
N/A
18.6 μJ
Pulse length
N/A
1 ms
Environmental Conditions
Transport
Ambient temperature
From -20 °C to 50 °C (max gradient 10 °C/hour)
Humidity
From 0 % to 95 % non-condensing
Atmospheric pressure
From 1080 hPa to 660 hPa (corresponding to an
altitude of -1000 m tp 3500 m)
EN 60068-2-32, Free fall
Consult
Operation
Ambient temperature for optimal scanning performance
From 22 °C to 25 °C
Allowed ambient temperature
From 0 °C to 45 °C
Humidity
From 0 % to 95 % non-condensing
Atmospheric pressure
From 1080 hPa to 660 hPa (corresponding to an
altitude of -1000 m tp 3500 m)
Maximum acceleration
20 ms
-2
EN 60068-2-32, Free fall
Consult
PhoXi 3D Scanner - User Manual and Installation Instructions
19/36