01/2020
Figure 10: Connecting the Scanner through router is not supported
Note:
■
Connecting to the Scanner via WiFi is not recommended as it is slower and less reliable.
NOTICE
If several Scanners are connected to a computer with several ethernet adapters, using static IP addresses on different
subnets is recommended.
Mounting Restrictions
Movement During Scanning
NOTICE
It is allowed to mount the scanner on moving constructions or robotic arms. Movement of the Scanner during projection
of light patterns causes loss of quality and interferes with depth calculation. Make sure the Scanner is still during
acquisition.
If vibrations are present, use damping apparatus to isolate Scanner’s mounting from their source. Acceleration and
deceleration forces according to Scanner’s environment restrictions should be taken into account when mounting of the
Scanner is designed.
The maximum acceleration allowed during operation (not including the scanning process) are up to 20 ms
-2
.
Strong Electric Field
As a general rule, always isolate low-voltage, logic-type devices such as PhoXi 3D Scanner from devices that are high
voltage and generate high electrical noise. Carefully consider the routing of the wiring for the devices in the panel as well.
Avoid placing low-voltage signal wires and communication cables in the same tray with AC power wiring and high energy,
rapidly-switched DC wiring.
Clearance for Cooling and Wiring
PhoXi 3D Scanners are designed to be cooled through natural convection cooling. In order to ensure adequate cooling, a
clearance of at least 25 mm above and below the device must be allowed. When planning placement of the PhoXi 3D
Scanner, consider placing heat-generating and electronic-type devices in the cooler areas. By reducing exposure to
high-temperature environments, you can extend the operating life of the electronic devices considerably.
PhoXi 3D Scanner - User Manual and Installation Instructions
14/36