01/2020
Cables
Following cables in
standard
or
industrial
quality are available for additional purchase:
■
Ethernet cable
■
Power cable (from power adapter to device)
All cables are available in following lengths:
■
3 m, 5 m, 10 m, 15 m
The industrial ethernet cables are sheathed in polyurethane jackets for high flexibility, durability and resistance to
chemicals, water and UV.
The industrial power cables are sheathed in flex polyvinyl chloride jackets for high flexibility and resistance to oils, water
and UV.
Custom Cables
Connecting the device to power and network by custom cables is allowed. In case custom cables are used, the user has to
ensure that correct voltage is reached at the device end. Longer custom cables should have wires of a larger diameter to
compensate for voltage losses. Adhere to electrical parameters in the following section when preparing custom cables.
When using custom cables, any damage caused to the device due to incorrect voltage is exempt from warranty.
Powering the device through the ethernet connector (PoE) is not possible.
⚠
CAUTION
Not ensuring correct voltage at the device end can negatively influence the correct functionality of the device or cause
permanent damage.
Projection Unit
Projection angle horizontal
47.5° ± 1°
Projection angle vertical
36.0°± 2°
Laser class 3R devices
Model
XS, S
M, L, XL
Light source
Visible red light (laser)
Visible red light (laser)
Wavelength
639 nm
637 nm
Average power
0.314 mW
4.32 mW
Pulse energy
382 nJ
93.7 μJ
Pulse length
0.96 ms
1.32 ms
PhoXi 3D Scanner - User Manual and Installation Instructions