Chapter 8: Controlling the Output
108
Keypad commands:
1) To enable
Vacation
Mode, press the [SENSOR ON/OFF] key,
then the [OUTPUT] key. The unit will respond by saying “ON”
to indicate that
Vacation
Mode is set. The
Suitcase
icon
will appear and blink on the thermostat LCD.
2) To enable
Normal
Mode, press the [SENSOR ON/OFF] key,
then the [OUTPUT] key. The unit will respond by saying “OFF”
to indicate that
Normal
Mode is set. The
Sun
or Moon
icon will appear on the thermostat LCD.
TouchTone Commands:
Call the Sensaphone. When the unit answers, it will begin reciting
a status report. At any time during the call, press a Touch-Tone.
The unit will respond with “OK.” The Sensaphone is now ready to
accept Touch-Tone commands.
1) To enable Vacation Mode, press SRO (776). The unit will
respond by saying “ON” to indicate that Vacation Mode is set.
The
Suitcase
icon
will appear and blink on the thermostat
LCD.
2) To enable Normal Mode, press SRO (776). The unit will
respond by saying “OFF” to indicate that Normal Mode is set.
The
Sun
or Moon
icon will appear on the thermostat
LCD.
3) To check the status of the ouput press WRO (976). The unit
will respond “OFF” for Normal Mode or “ON” for Vacation
Mode.
4) Hang up.
8.3.2 Dual Thermostat Control
When a three or four wire low voltage thermostat is used, it is
easy to connect the Sensaphone to your furnace with the addition
of a secondary thermostat. One thermostat is set to your preferred
“away” temperature and the other thermostat is set to your
preferred “home” temperature. With your Sensaphone 800, you
Summary of Contents for Sensaphone 800
Page 2: ......
Page 3: ...SENSAPHONE Model 800 User s Manual Version 1 1 PHONETICS INC ...
Page 14: ...Sensaphone Model 800 User s Manual xii ...
Page 20: ...xviii ...
Page 42: ...Sensaphone Model 800 User s Manual 39 ...
Page 70: ...Sensaphone Model 800 User s Manual 67 ...
Page 130: ...127 ...
Page 132: ...129 ...
Page 136: ...133 ...