2 Specifications

Part No.  

4030990

Power  

115 VAC, 60 hz.

Operating  

3 – 0°, 45°, 90° 

Positions
Drive Motor 

1 /3 Horsepower, 2-Speed

Motor  

Thermal cut-off

Protection 

Cord Length   20 Feet
Airflow  

2800 ft/min outlet velocity

Current Draw   2.6 Amps High speed, 2.0 Amps Low speed
Warranty  

One Year - 100% parts and labor  

 

(all components)

 

Three Years - Only materials and workmanship  

 

of the housing are covered.

3 Power Requirements

3.1 Daisy Chaining

The Phoenix Centrifugal Air Mover draws 2.6 amps. The 12 

amp, on-board circuit breaker will allow 

four (4) 

Phoenix 

Centrifugal Air Movers on one circuit. When daisy-chaining 

the Phoenix Centrifugal Air Mover, turn on one Phoenix 

Centrifugal Air Mover at a time to prevent excessive current 

inrush caused by four units starting at once.
A ground fault in the Phoenix Centrifugal Air Mover Pro or 

anywhere on the circuit will cause the Phoenix Centrifugal 

Air Mover’s GFCI to trip. After rectifying the ground fault, 

reset the GFCI by pressing the reset button.

•  Use only Manufacturer’s recommended attachments. 

Contact Therma-Stor for proper repair instructions.

•   Do not pull or carry it by the power cord, use cord as a 

handle, close doors on cord or pull cord around sharp 

edges.

•  Do not run or drive over cord.
•  Keep cord away from heated surfaces.
• Do not handle power cord plug with wet hands.
• Turn off all controls before unplugging.
•  Do not use when you are tired, distracted or under the 

influence of drugs, alcohol or medication.

LIRE ET CONSERVER CES INSTRUCTIONS

•  Risque de choc électrique Peut causer des blessures ou 

la mort. Débrancher toutes les alimentations en courant 

électrique à distance avant l’entretien ou le nettoyage.

•  Ne pas utiliser l’appareil avec un cordon d’alimentation 

coupé ou effiloché.

•  Ne pas débrancher l’appareil en tirant sur le cordon. Tenir 

la fiche fermement et la tirer hors de la prise murale ou 

la prise d’alimentation électrique.

•  Toujours utiliser une prise mise à la terre.
•  Ne jamais utiliser l’équipement électrique dans de l’eau 

stagnante.

•  Ne jamais utiliser sans les grilles de protection. Des 

blessures risquent d’en résulter.

•  Ne pas brancher plus de 8 ampères au total au 

différentiel.

•  Vérifier la protection du différentiel avant chaque 

utilisation en appuyant sur le bouton “ test “. Si l’appareil 

fonctionne correctement, le bouton “ reset “ ressort.

•  Ne pas passer les doigts ou d’autres objets dans les 

grilles de protection.

•  Ne pas diminuer le débit d’air arrivant jusqu’à l’appareil. 

L’appareil risque de trop chauffer.

•  Ne pas s’asseoir ou se tenir debout sur l’appareil; ne pas 

l’utiliser comme étagère ou table.

•  Avant de laisser un appareil aéraulique axial sans 

surveillance, s’assurer que les enfants n’ont pas accès 

à l’équipement. Ne pas laisser les enfants jouer avec 

l’appareil ou à proximité de l’appareil ou dans l’air qu’il 

projette.

•  Pour réduire le risque d’incendie ou de choc électrique, 

ne pas utiliser ce ventilateur avec un dispositif de 

commande de vitesse à semi-conducteurs.

Dimensions Machine 

Shipping

Width  

17.25”  

17.3”

Height  

20”  

20”

Depth  

19.4”  

20”

Weight  

27 lb  

30 lb

5

Figure 1: Too many Centrifugal Air Movers daisy-chained

Summary of Contents for Stackable CAM Pro

Page 1: ...AM Pro is ETL Listed UL Certified The Phoenix Stackable CAM Pro is also lightweight and properly balanced for easy handling Other convenience features include a lighted cord for easier determination of power to the outlet and superior cord management for better handling packing and storage The Phoenix Stackable Centrifugal Air Mover Pro 2 Speed 1 3 Horsepower Motor 2 6 Amps on High Speed 2 0 Amps ...

Page 2: ...ginally installed after servicing or cleaning the product Never place your face hands or other susceptible body parts in the air stream inlets or outlet of this device This fan is not a toy Ensure children do not play with and do not have access to the equipment Do not allow children to play with or stand near the unit or in its air flow Do not use this fan with any solid state speed control devic...

Page 3: ...ohol or medication LIRE ET CONSERVER CES INSTRUCTIONS Risque de choc électrique Peut causer des blessures ou la mort Débrancher toutes les alimentations en courant électrique à distance avant l entretien ou le nettoyage Ne pas utiliser l appareil avec un cordon d alimentation coupé ou effiloché Ne pas débrancher l appareil en tirant sur le cordon Tenir la fiche fermement et la tirer hors de la pri...

Page 4: ...sephoenix com sales thermastor com Toll Free 1 800 533 7533 4 Operation Instructions The Phoenix Centrifugal Air Mover is intended for use by water damage restoration carpet cleaning construction and janitorial sanitation professionals in general ventilating and structural surface drying applications The Phoenix Centrifugal Air Mover as packaged is ready to be put into service Inspect the unit com...

Page 5: ...nouts Rotate the second fan down into position until the grills engage If the fans will be transported while stacked they must be securely strapped into position 7 Maintenance WARNING Disconnect the unit from power before servicing or cleaning Replace the safety grill after servicing lubrication or cleaning 7 1 Servicing Before each use inspect for damage blocked inlet or outlet or any excess buil...

Page 6: ...6 USEPHOENIX COM 1 800 533 7533 PUR WHT WHT LOW HIGH M 1 2 3 4 5 HOT NEUTRAL BREAKER T H W K L B WHT BLK LOAD LINE GROUNDED GFCI DUPLEX PLUG 12 AMP CIRCUIT WHT 6 ORG 9 Wiring Diagram ...

Page 7: ... cause beyond Therma Stor LLC s reasonable control If any Phoenix Centrifugal Air Mover part is repaired or replaced the new part shall be warranted for the balance of original warranty but all warranty periods will be extended by the period of time if any that the Phoenix Centrifugal Air Mover is out of service while awaiting covered warranty service Warranty service will be performed during norm...

Reviews: