5.4 GFCI Protection and the On-Board Duplex
Outlet
The standard AC voltage outlet GFCI (Ground Fault Circuit
Interrupter) promotes operator safety in wet applications.
GFCI devices trip when a fault to electrical ground is sensed.
It is recommended to check the GFCI protection prior to
operation. To check, push the “TEST” button located on the
GFCI duplex outlet will pop out. If operating properly the
“RESET” button on the GFCI outlet will pop out. Depending
on your Centrifugal Air Movers specific equipment, a tripped
GFCI may be indicated by a small LED. The device can only
be “RESET” when the Centrifugal Air Mover is connected to a
wall outlet providing standard voltage. This duplex AC outlet
allows the inter-connection of other AC powered devices. The
sum total amperage of all devices (excluding the first fan)
plugged into the receptacle must not exceed 8.5 amps.
6 How to Stack
Place your first fan on the floor, motor side down. Pick up
your second fan and orient it above the first fan. Engage
the alignment nubs on the side of both snouts. Rotate the
second fan down into position until the grills engage. If the
fans will be transported while stacked, they must be securely
strapped into position.
Low Speed:
Quiet Operation
7 Maintenance
WARNING: Disconnect the unit from power before servicing
or cleaning. Replace the safety grill after
servicing, lubrication or cleaning.
7.1 Servicing
Before each use, inspect for damage, blocked inlet or outlet,
or any excess buildup of foreign material.
Inspect the GFCI to ensure it is not in a “tripped” condition.
Push “RESET” to reset the GFCI.
When the Phoenix Centrifugal Air Mover Pro is first turned
on, check for excessive vibration. If the unit vibrates
excessively or if blower wheel rubs on housing, turn off the
unit immediately. Have a service technician inspect the unit
to locate the problem.
7.2 Cleaning
The housing is made of a durable and washable
polyethylene. When cleaning, the use of solvents is NOT
recommended.
8 Replacement Parts and
Optional Accessories
4030989 motor, 60HZ
4027572 blower wheel
4029721 rocker switch
4025458 red pilot light
4029742 cord
4030982 inlet grill, motor side
4030983 inlet grill, wheel side
4030984 grill, snout
4025203 breaker
4025205 GFCI
Contact the factory at 1-800-533-7533 to order
replacement parts, or optional accessories
PNs 4030990 and
4030980 are pictured
to demonstrate
maximum stackability.